# Service Engineer Academy > Online, self-paced courses for medical equipment service engineers (biomedical / HTM / field service): MRI, CT, X-ray, ultrasound, anesthesia, ventilators, dialysis, defibrillators, lab, dental and more. Each course has short lessons with figures, a timed final exam and a verifiable certificate. Operated by Service Engineer Ltd (Astana International Financial Centre, Kazakhstan). Prices in USD, pay by card (Paddle) or by company invoice. Contact: ceo@serviceengineer.app Who it is for: in-house biomedical / clinical engineering staff, independent service organizations (ISOs), field service engineers, technical experts who investigate equipment failures, and managers who need documented training of their engineers. Team access: every course can be bought for a team; companies can request an offer and invoice at https://serviceengineer.academy/quote/ ## Courses - [Aeonmed Aeon 7200 / 7200A Anaesthesia Machine — Model Service](https://serviceengineer.academy/course/aeon-7200/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the Aeon 7200A apart on paper: pipeline and cylinder inputs, the pneumatic O2 failure warning and N2O cut-off, the flowmeter bank with its O2-N2O link, the vaporiser manifold, the circle and absorber, the bellows and the O2-driven ventilator with its sensors, boards and battery. Then the engineer's checkout with your own instruments against the manufacturer's values, the maintenance schedule and its gaps, fault-finding from alarm group and test point to a proven part, and a complete return to service with electrical safety and a record. Independent course: not affiliated with or endorsed by Beijing Aeonmed Co., Ltd. Aeonmed and Aeon are trademarks of their owner; other names are trademarks of their respective owners. - [Anaesthesia Machine Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/anes-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to check, maintain and verify an anaesthesia workstation. Level 2 starts when the checkout fails anyway, or passes while the anaesthetist still complains. This course teaches the engineer to read the checkout result and the machine's log as evidence, split the machine into gas supply, flow control, vaporisers, breathing system, ventilator and monitoring, and separate them with a test lung, an analyser and the machine's own tests until one module is left - and then prove the repair and write down who decides that the machine is fit for use. - [Angiography and C-arm Service — Level 1](https://serviceengineer.academy/course/angio-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. Mobile C-arms wear out from transport and handling long before their tube does, and fixed angiography rooms stop on a potentiometer, a brake or a lost connection far more often than on a failed generator. This course teaches the engineer who maintains C-arms and angiography systems to keep them safe for staff and patients, to understand the imaging chain well enough to tell a fault from a setting, and to run a planned maintenance that finds wear before the surgeon does. - [Angiography and C-arm Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/angio-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep a C-arm or an angiography room safe, maintained and measured. Level 2 starts when it fails anyway, usually with a patient on the table. This course teaches the engineer to read the logs of mobile C-arms and fixed angiography systems for the first and causal event, to isolate the fault between the stand and the workstation, the generator and the tube, the image chain and the detector, the motion system and the software, and to follow it to the module that has really failed. Then it shows how to return the system to clinical use with the tests, dose checks, safety tests and written records that prove the repair. - [bioMérieux mini VIDAS Immunoassay Analyser — Model Service](https://serviceengineer.academy/course/biomerieux-mini-vidas/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Lab Analyser Service — Level 1, and ideally Level 2. It takes the mini VIDAS apart on paper: the ELFA strip and SPR, the two independent sections with their heated blocks, trays and six-channel pipettors, the flash-lamp fluorometer on its moving scanner, the solid standard and auto-calibration, and the three levels of controller boards. Then the work itself: start-up, temperature and QCT checks, calibration strips and what QC proves, the annual maintenance in the right order, fault-finding from the four error groups to one section and one assembly, part replacement with the follow-up each part needs, the section, scanner and optics adjustments, and a return to service that waits for the laboratory's standards and QC. Independent course: not affiliated with or endorsed by bioMérieux. bioMérieux, VIDAS and mini VIDAS are trademarks of their owner; other names are trademarks of their respective owners. - [Canon (Toshiba) Aquilion CT — Model Service](https://serviceengineer.academy/course/canon-aquilion/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed CT Service — Level 1. It takes the Aquilion family apart on paper: Aquilion 16, 32 and 64, ONE, Prime and Prime SP, LB and CXL. Its gantry, couch and consoles by the names its documentation uses, the warm-up and calibration order, the backups that save a reinstall, the PM wear points engineers actually find, fault-finding from over kV to a degraded RAID, and tube, disk and software replacement with the calibrations and checks before release. Built on resolved field cases. Independent course: not affiliated with or endorsed by Canon Medical Systems or Toshiba. Canon, Toshiba and Aquilion are trademarks of their owners. - [Criticare nGenuity 8100E Vital Signs Monitors — Model Service](https://serviceengineer.academy/course/criticare-ngenuity/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Patient Monitor Service — Level 1. It takes the nGenuity 8100E, 8100EP, 8100E1 and 8100EP1 apart on paper: the Main Board that also carries the NIBP transducer, the ECG/Analog and DOX SpO2 boards, the power module and lead-acid battery, the printer and CO2 modules, the service windows and what each check proves, the maintenance schedule, fault-finding from symptom to assembly, and a return to service with calibration, software and safety handled correctly. Independent course: not affiliated with or endorsed by Criticare. Criticare, nGenuity, DOX and ComfortCuff are trademarks of their owner; other names are trademarks of their respective owners. - [CT Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/ct-l2/) — Level 2; 10 lessons, 6 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep a CT scanner safe, calibrated and maintained. Level 2 starts when it stops anyway. This course teaches the engineer to read the error log for the first error rather than the loudest, place the failure in the scan sequence, and follow it through the tube, the high-voltage generator, the slip ring, the detector, the gantry, the table and the computers to the subsystem that has actually failed - and then prove the repair with the calibrations, phantom tests and records the manufacturer requires. - [Defibrillator and ECG Service — Level 1](https://serviceengineer.academy/course/defib-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. Most defibrillators that fail on the ward fail for small reasons: a tired battery, expired pads, a cracked cable, a sync button left on, a self-test warning nobody read. This course teaches the engineer who looks after manual defibrillators, AEDs and ECG machines to work safely around stored high energy, to test delivered energy, charge time and synchronised cardioversion with an analyser, to keep devices ready between uses, and to find the common ECG and printer faults. - [Defibrillator and ECG Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/defib-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to test a defibrillator with an analyser, keep its battery and pads in date and find the common ECG faults. Level 2 starts when the device fails anyway. This course teaches the engineer to read self-test and event logs for the first cause, to separate power, charge, storage, delivery and monitoring with the cheapest test that tells them apart, to follow the fault to the battery, the charger, the capacitor, the switching stage, the cable, the pacer, the ECG front end or the printer, and to return the device to service with the measurements and records that prove it. Stored energy is treated as the first hazard in every lesson. - [Dental Equipment Service — Level 1](https://serviceengineer.academy/course/dental-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A wet compressor, a clogged filter in the floor box, a suction unit full of foam, a handpiece oiled the wrong way - most dental calls start with something outside the part that gets blamed. This course teaches the engineer who maintains a dental practice to see the whole installation and keep it safe and working. - [Dental Equipment Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/dental-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to see the whole dental installation and keep it safe and maintained. Level 2 starts when something stops anyway. This course teaches the engineer to read the code and the symptom, place the fault on a map of air, water, suction, power and control, prove it with a gauge, a meter or a swap, and follow it through the unit, the handpieces, the compressor and suction plant, the intraoral, panoramic and CBCT X-ray units and the autoclave to the part that has actually failed - and then return the equipment to service with the tests and records that show it is fit for patients. - [Dialysis Equipment Service — Level 1](https://serviceengineer.academy/course/dialysis-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A dialysis machine is the last link in a chain that starts at the city water inlet. Poor water, a wrong concentrate, a reused filter or a conductivity system that agrees with itself and is wrong can all harm a patient while every screen looks normal. This course teaches the engineer who maintains dialysis equipment to keep the whole chain safe, verified and documented. - [Dialysis Equipment Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/dialysis-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep a dialysis unit safe, disinfected and maintained. Level 2 starts when a machine keeps failing anyway. This course teaches the engineer to read the alarm and self-test history for the first cause, trace the fault on the hydraulic diagram of the exact machine, split the blood side from the dialysate side and the machine from its water and concentrate supply, and follow the fault through pumps, valves, degassing, balancing, conductivity, the heater, the blood module, disinfection and the water plant to the part that has really failed, without ever weakening a protective system. It ends with peritoneal cyclers, multi-cause cases and the tests and records that let the responsible person decide whether a machine may treat patients again. - [Digital X-ray Detectors — Level 2](https://serviceengineer.academy/course/dr-detectors/) — Level 2; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A calibration taken with the grid in place, a wireless link that gives up half a second too early, a battery that is not the original, a panel that was stood on — most 'dead detector' calls start with something that can be found in an hour if you know where to look. This course teaches the engineer who already services X-ray rooms to understand flat-panel detectors from the inside, keep them calibrated, read their artefacts, integrate them with generators and networks, and tell a real detector failure from everything that only looks like one. - [Dräger Fabius Anaesthesia Workstations — Model Service](https://serviceengineer.academy/course/draeger-fabius/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the Fabius family apart on paper, with the Fabius GS as the reference machine: the gas box, the S-ORC, the electric piston ventilator and its pneumatic assembly, the compact breathing system, the engineer's checkout with the manufacturer's limits, the six-monthly PM with its one- and three-year kits, service-mode calibrations in a sound order, service log codes, leak isolation, ventilator, flow sensor and O2 cell faults, the power chain and lost-memory faults, and a full return to service. Independent course: not affiliated with or endorsed by Drägerwerk AG. Dräger and Fabius are trademarks of their owner. - [Dräger Primus Anaesthesia Workstation — Model Service](https://serviceengineer.academy/course/draeger-primus/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the Primus apart on paper, following its technical documentation: the modules on the CAN bus and the neutral point board, the gas inlet block and the electronic mixer with its tank and proportional valve, the safety O2 adjuster, the VGC with its piston-cylinder unit, rolling seals and vacuum, the heated compact breathing system, the PGM and PGM2 gas monitors, the power pack and UPS batteries. Then the cold start and the manufacturer's test list with its limits, the maintenance parts and what the machine calibrates by itself, alarms and safety mode, leak, ventilator, flow and gas monitoring faults, power and board faults, typical replacements and a full return to service. Engineers who know the Fabius are told where the Primus differs. Independent course: not affiliated with or endorsed by Drägerwerk AG. Dräger and Primus are trademarks of their owner. - [Endoscopy Equipment Service — Level 1](https://serviceengineer.academy/course/endo-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A bitten insertion tube, a skipped leak test, a scope soaked with the wrong cap, a lamp run past its life, a washer whose hose has been dissolving for a year — most endoscopy downtime and most expensive repairs start with handling, reprocessing and simple checks that nobody owned. This course teaches the engineer who looks after an endoscopy unit how the tower, the scopes and the reprocessing equipment work, what to check, and what to hand on to a specialist. - [Endoscopy Equipment Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/endo-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you how the tower, the scopes and the reprocessors work and how to check them. Level 2 starts when the check fails and the obvious swap does not help. This course teaches the engineer to read the processor and reprocessor logs, run swap tests that actually separate two suspects, follow the image and light chains to the failed board, lamp, cable or seal, localise a leak or an angulation fault in a flexible scope, decide honestly what can be repaired in the field and what must go to a specialist, and return the equipment to service with tests and records that hold up. - [Eschweiler Combiline Blood Gas and Electrolyte Analyser — Model Service](https://serviceengineer.academy/course/eschweiler-combiline/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Lab Analyser Service — Level 1 and ideally Level 2. It takes the Eschweiler combiline apart on paper: the builds and how to tell them apart, the rebuildable sensors, the liquid calibrants in bags instead of gas cylinders, the sample light barrier that decides most transport faults, the thermostat with its separate regulation and indication circuits, and the few boards behind them. Then it covers start-up and calibration data as evidence, the service test programs, QC levels and what each proves, maintenance of membranes, tubing and pumps, fault-finding from message group to part, and repair with the follow-up adjustments in the right order and a proper return to service. Independent course: not affiliated with or endorsed by Eschweiler. Eschweiler and combiline are trademarks of their owner; other names are trademarks of their respective owners. - [Electrosurgical Unit Service — Level 1](https://serviceengineer.academy/course/esu-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. Most electrosurgical burns and 'generator faults' start with a lifted return pad, a cracked cable, a sticking footswitch or an untested alarm. This course teaches the engineer who looks after electrosurgical generators to test them properly, keep their accessories safe and handle an incident without destroying the evidence. - [Electrosurgery Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/esu-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to test an electrosurgical generator with an analyser, keep its accessories safe and find the common faults in theatre. Level 2 starts when the simple answers run out. This course teaches the engineer to read error codes and logs for what the controller noticed, to separate the generator, the accessories, the return electrode circuit, the activation path and the operating room around them, to follow no output, low output, false alarms and interference to the stage that causes them, and to return a generator to service with the measurements and records that prove it. After a burn or a fire, it teaches you to preserve the evidence first. - [Fault-Finding Method for Medical Equipment](https://serviceengineer.academy/course/fault-finding-method/) — General; 6 lessons, 3 h, certificate; $49 per engineer, team of 5 $190. A sterilizer that aborts with a vacuum error and turns out to have a flat backup battery. A CT detector that reboots at random while seven good boards are replaced. A test that fails because the wrong test bag was used. Most lost hours in service are not lost on hard faults; they are lost on guessing. This course teaches the loop that experienced engineers run in their heads on every job: collect the facts, list the hypotheses, choose the cheapest test that separates them, measure instead of assuming, find the root cause, and return the machine to service safely with a report that the next engineer can use. Every lesson is built on real resolved cases from MRI, CT, X-ray, ultrasound, laboratory, sterilization, dental, anaesthesia and ventilation equipment. - [Flight Medical Flight 60 and 60T Ventilators — Model Service](https://serviceengineer.academy/course/flight-60/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ventilator Service — Level 1, and ideally Level 2. It takes the Flight 60 with its piston manifold and the Flight 60T with its blower apart on paper: the gas path, the three oxygen arrangements, the boards and the power section; the power-on self-test, the circuit test and every step of the Operational Verification Procedure with analyser, test lung and resistors; the hour and calendar limits, filters, sensors and batteries; fault-finding from the error table to the faulty module; and repair with the right calibrations, software handled correctly, electrical safety and a complete record. Independent course: not affiliated with or endorsed by Flight Medical Innovations. Flight Medical and Flight 60 are trademarks of their owner; other names are trademarks of their respective owners. - [Fresenius 4008 Haemodialysis Machines — Model Service](https://serviceengineer.academy/course/fresenius-4008/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Dialysis Equipment Service — Level 1 and ideally Level 2. It takes the 4008 S apart on paper, with the E, B and H differences where they matter: the hydraulic path from water inlet to drain with its numbered parts, the balancing chamber and UF pump, concentrate and bicarbonate dosing, the blood pump, heparin pump and air detector modules, the two CPUs and the power supply. It then reads the T1 test step by step and shows what each step proves and what it does not, walks through the technical safety checks and maintenance list, decodes the error groups from T1 F-codes to UF failures, and ends with repair and return to service. Independent course: not affiliated with or endorsed by Fresenius Medical Care. Fresenius, Fresenius Medical Care, 4008, 5008, bibag, DIASAFE, ONLINEplus and Puristeril are trademarks of their owner; other names are trademarks of their respective owners. - [GE Brivo OEC 850 Mobile C-arm — Model Service](https://serviceengineer.academy/course/ge-brivo-oec850/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Angiography and C-arm Service — Level 1, and ideally Level 2. It takes the Brivo OEC 850 apart on paper: the mechanics and brakes, the resonant inverter and the monoblock, the collimator, intensifier, camera and CCU, the workstation and the interlock loop; the manual's function, generator, image and dose checks; a full periodic maintenance; fault-finding from the panel code and the log to one replaceable unit; and repair with the calibrations, safety tests and paperwork that must follow. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Brivo and OEC are trademarks of their owner; other names are trademarks of their respective owners. - [GE Carestation 620/650 Anaesthesia — Model Service](https://serviceengineer.academy/course/ge-carestation/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the Carestation 620, 650 and 650c apart on paper: supplies read by sensors instead of gauges, needle valves with Link-25 inside an electronic gas control module, the flow-valve and bellows ventilator, the compact breathing system and its flow sensors, the automated Full Test and the manual checks it does not replace, user and planned maintenance with GE's 12-, 24- and 48-month parts, alarms read as pointers to assemblies, the safety notices for this family, and a repair and return to service you can defend. Where the older Datex-Ohmeda machines (Aespire, Avance, Aisys) share a concept, the course says so. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Carestation, Datex-Ohmeda, Aespire, Avance, Aisys, CARESCAPE, D-fend, Tec and Selectatec are trademarks of their respective owners. - [GE Corometrics 170 Series Fetal Monitors — Model Service](https://serviceengineer.academy/course/ge-corometrics-170/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Patient Monitor Service — Level 1. It takes the Corometrics 171, 172, 173 and 174 apart on paper: how pulsed Doppler, direct FECG, toco and intrauterine pressure reach the strip chart, how the plug selects the mode, the main board, FECG/IUP board and recorder, the functional checkout with a fetal simulator, timed chart-speed and paper-scale checks, latching FHR alarms and leakage on every applied part, transducer care and cleaning compatibility, fault-finding from chart messages to the faulty plug, transducer or board, and repair and release with settings, software and safety handled correctly. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Corometrics and Nautilus are trademarks of their owners; other names are trademarks of their respective owners. - [GE LOGIQ Ultrasound — Model Service](https://serviceengineer.academy/course/ge-logiq/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1 and, ideally, Ultrasound Probes. It takes the LOGIQ e apart on paper: its master board, back end PC, power and battery, probe port and docking cart; the power-up as a diagnostic sequence; the functional checks and the service platform; preventive maintenance with the manufacturer's safety limits; fault-finding from boot to DICOM with real cases from LOGIQ e, P, S, E and F systems; and replacement, software reload and return to service. Where cart LOGIQs differ, the course says so in general terms. Independent course: not affiliated with or endorsed by GE HealthCare. GE and LOGIQ are trademarks of their owner. - [GE LOGIQ P8, P9 and P10 Ultrasound — Model Service](https://serviceengineer.academy/course/ge-logiq-p/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1 and Level 2 and, ideally, the GE LOGIQ model course. Where that course follows the portable LOGIQ e, this one takes apart the LOGIQ P8, P9 and P10 cart platform: the nest box with its probe interface, core board, front-end supply, I/O box and PC module; the hardware releases from R1 to R4.5 and why they decide which part fits; the start-up, the service desktop access classes and what each built-in diagnostic proves; maintenance to the manufacturer's care schedule with both air filters, probes, controls and backups; fault-finding from the error log to the board, the probe port or the hospital network, with real cases from the LOGIQ P family; and replacement, software and settings handled so that the system identity, options and patient data survive. Independent course: not affiliated with or endorsed by GE HealthCare. GE and LOGIQ are trademarks of their owner; other names are trademarks of their respective owners. - [GE Mac-Lab and CardioLab Hemodynamic Recording Systems — Model Service](https://serviceengineer.academy/course/ge-mac-lab/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Angiography and C-arm Service — Level 1. It takes the Mac-Lab, CardioLab and ComboLab recording systems on software 6.5.6 apart on paper: TRAMNet and the CardioLab II Plus amplifier, the acquisition computer and its boards, the IEB and UPS, review stations, the Centricity Cardiology INW server and the DICOM and HL7 links to the X-ray system and the CVIS. You learn the manufacturer's checkout with a patient simulator, electrical safety of a medical electrical system with intracardiac connections, backups that really restore, fault-finding from signal noise to domain and replication faults, and recovery and return to service without losing patient data. Independent course: not affiliated with or endorsed by GE HealthCare. Mac-Lab, CardioLab, Centricity, TRAM and TRAMNet are trademarks of their owner; other names are trademarks of their respective owners. - [GE Revolution EVO and Maxima CT — Model Service](https://serviceengineer.academy/course/ge-revolution-ct/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed CT Service — Level 1, and a natural companion to Level 2. It takes the Revolution EVO and Revolution Maxima apart on paper: gantry and slip ring, tube, generator and Clarity detector, tables and consoles under the names their documentation uses, the power chain from the main disconnect through the PDU and partial UPS, room climate and network. Then the routine and what each check proves, planned maintenance in a safe order, fault-finding from the first error in the log, and replacements with the calibrations, dose and safety checks that must come before patients. Built on resolved field cases. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Revolution, Revolution EVO, Revolution Maxima, Optima, BrightSpeed, LightSpeed, Clarity and Performix are trademarks of their owner; other names are trademarks of their respective owners. - [GE SIGNA MRI — Model Service](https://serviceengineer.academy/course/ge-signa/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed MRI Service — Level 1, continuing the Sumitomo cryocooler course. It takes the GE SIGNA 1.5T and 3T family as engineers meet it — HD, HDe, HDxt, Excite, Creator, Explorer, Voyager and Pioneer — and goes family-specific: how the generations package magnet monitoring, gradients, RF, computers and cooling; the daily readings that show a drift; the PM of chiller, gradient cooling, shield, coils and cabinets; fault-finding with real field cases; and where an independent engineer's work ends and the manufacturer's begins. Independent course: not affiliated with or endorsed by GE HealthCare. GE, SIGNA and the system names mentioned are trademarks of their owners. - [GE Venue 50 Point-of-Care Ultrasound — Model Service](https://serviceengineer.academy/course/ge-venue-50/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1, and ideally Level 2. It takes the Venue 50 apart on paper: the tablet console with its front-end and master boards, the docking station and cart with their power path, ports and three-probe box, the power module and batteries. You learn the checks and what each proves, the electrical safety tests with the manufacturer's limits, care and battery maintenance, fault-finding by splitting console from dock and probe from port, and a return to service with data, settings, software and options handled the manufacturer's way. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Venue and LOGIQ are trademarks of their owner; other names are trademarks of their respective owners. - [GE Versana Balance Ultrasound — Model Service](https://serviceengineer.academy/course/ge-versana-balance/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1 and Level 2. It takes the Versana Balance VA and VS apart on paper: the internal cage with the CWI, MST, PIB and optional CWD boards, the docking board, the power box with its single DC supply, the monitor, panel and three probe ports; the two software lines tied to two MST generations; the start-up, the rear diagnostic LEDs and the service desktop access classes; maintenance to what the manufacturer actually requires, with filters, cleaning, probes, backups and records; fault-finding from black screen, system message or noisy image to the responsible assembly, with real cases from the Versana and related GE families; and replacement, software reload and settings restore handled so that the system keeps its identity, options and patient data. Independent course: not affiliated with or endorsed by GE HealthCare. GE and Versana are trademarks of their owner; other names are trademarks of their respective owners. - [GE Vivid 7 and Vivid i Cardiovascular Ultrasound — Model Service](https://serviceengineer.academy/course/ge-vivid/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1 and, ideally, Level 2 and Ultrasound Probes. It takes two machines apart on paper: the Vivid 7 cart, with its card rack of separate front end boards, PC back end with UPS battery and isolating transformer, and the Vivid i portable, with its three-board front end, power supply, lithium-ion battery and five fans. It reads the power-up of each as a diagnostic sequence, explains the service platform logs and built-in tests, follows the manuals' preventive maintenance with GE's safety limits, localises faults from no boot to a single dead probe with field cases from the Vivid family, and covers replacement, calibration, software at procedure level and return to service. Engineers who know LOGIQ are told where Vivid is different. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Vivid and LOGIQ are trademarks of their owners. - [Power and Cooling for Medical Equipment](https://serviceengineer.academy/course/infra-l1/) — Repair fundamentals; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. CT, MRI, angiography and X-ray systems depend on things their manufacturer does not build: the mains supply and earthing, the UPS and generator, the chiller and its water loops, and the air conditioning of the scan room and equipment room. When one of them weakens, the scanner shows it as a tube that will not cool, a gradient that trips, a magnet that loses helium or a console that freezes. This course teaches the engineer to see the site behind the machine, to find infrastructure faults by method, to work safely on UPS battery banks and mains equipment, and to keep power and cooling under planned maintenance together with the facility team and the manufacturer. - [Power and Cooling for Medical Equipment — Level 2: Fault-Finding](https://serviceengineer.academy/course/infra-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to see the building behind the scanner: the supply, the UPS, the chiller, the loops and the room air, and who owns each of them. Level 2 starts when one of those links has failed and everybody says it is somebody else's. This course teaches the engineer to put the logs of the scanner, the UPS and the chiller on one timeline, to prove which link failed with recordings and trends, and then to follow the fault inside that link: rectifier, inverter, bypass and battery string in the UPS; sags, neutral and earth faults, generators and transfer switches in the supply; compressor, condenser, expansion and pressure faults in the chiller; pumps, flow switches, strainers, air and water quality in the loops; and the HVAC of the scan and equipment rooms. It ends where the real work ends: restarting an imaging system safely after a power or cooling failure, with the checks and records that prove it is ready. - [Infusion and Syringe Pump Service — Level 1](https://serviceengineer.academy/course/infusion-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. Infusion and syringe pumps are the most numerous powered devices in a hospital, and they deliver drugs where a few millilitres too many or too few matter. Most faults are mundane: a syringe the pump does not like, a tired battery, a sticky key, dried glucose in the mechanism. This course teaches the engineer to tell a real pump fault from a set or use problem, to test flow, occlusion and air detection properly, and to hand a pump back only when it is safe. - [Infusion and Syringe Pump Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/infusion-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to test a pump with an analyser, to suspect the syringe or set before the pump, to keep batteries and PM in order and to sequester a pump after an incident. Level 2 starts when the pump still fails with the right disposable in it. This course teaches the engineer to read error codes and event history as evidence, to reproduce the fault on the analyser, and to follow it to the drive, the pressure or air sensing, the position sensors, the battery and power path, the electronics, the software or the network, and then to prove the repair with flow, occlusion, air and alarm tests and an electrical safety test. It never teaches service codes, counter resets or ways around protection. - [Konica Minolta DRYPRO SIGMA Laser Imager — Model Service](https://serviceengineer.academy/course/km-drypro-sigma/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Medical Imagers and Film Printers — Level 1. It takes the DRYPRO SIGMA apart on paper: the cartridge, rollback and vacuum pick-up, the laser imaging assembly, the heated drum processor, the densitometer and the two boards that run it all; start-up, automatic calibration and the test prints that prove each half of the machine; the film-count maintenance with drum, processor and filter work; fault-finding from the condition code and the logs to one part; and repair and release with configuration, software and safety handled correctly. Independent course: not affiliated with or endorsed by Konica Minolta. Konica Minolta and DRYPRO are trademarks of their owner; other names are trademarks of their respective owners. - [Lab Analyser Service — Level 1](https://serviceengineer.academy/course/lab-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A cracked tube, a worn syringe seal, a tired lamp, a blocked waste line, a reagent topped up on old — most analyser faults start with something small in the fluidics, the optics or the routine. This course teaches the engineer who maintains laboratory analysers to work safely around blood and reagents, find faults by symptom and hand the machine back ready for the laboratory's QC. - [Lab Analyser Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/lab-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to work safely around an analyser, keep its fluidics, optics and temperatures in order and hand it back for the laboratory's QC. Level 2 starts when the analyser fails anyway and the cheap causes are already ruled out. This course teaches the engineer to read the event log and the QC history together, place a fault in one subsystem, prove it with the analyser's own service tests and a simple bench experiment, and follow it through the fluidics, the photometer, the haematology counting channels, the chemiluminescence reader, the blood gas sensors, the thermal and mechanical systems and the LIS link. And then to return the analyser with evidence that the laboratory can trust, without confusing the engineer's job with the laboratory's decision. - [Mammography Service — Level 1](https://serviceengineer.academy/course/mammo-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A paddle that creeps, a thickness reading a centimetre out, a detector calibrated cold, a grid that sticks — in mammography small faults cost image quality and dose for every woman screened. This course teaches the engineer who maintains a mammography unit what makes it different from general X-ray and how to keep it safe, calibrated and fit for screening. - [Mammography Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/mammo-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep a mammography unit safe, compressed correctly, calibrated and inside its QC programme. Level 2 starts when it fails anyway. This course teaches the engineer to read the error log together with the QC history, place the fault in the exposure sequence, and follow it through compression, the tube and generator, target and filter, the AEC, the detector, the C-arm, biopsy and tomosynthesis hardware and the workstations to the part that has actually failed - and then hand the unit back with the tests, physicist involvement and records a screening tool needs. - [Mindray WATO EX Series — Model Service](https://serviceengineer.academy/course/mindray-wato-ex/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the WATO EX-20/25/30/35 apart on paper: its gas path and boards, the checkout as this machine needs it, the one- and three-year kits, the system test and the order of calibrations, technical alarms, section-by-section leak finding, the valves-test tool, electrical faults and a full return to service. Independent course: not affiliated with or endorsed by Mindray. Mindray and WATO are trademarks of their owner. - [Patient Monitor Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/mon-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to test every channel and to swap the accessory first. Level 2 starts when the new cable did not help. This course teaches the engineer to read technical alarms and error histories, isolate one parameter at a time with a simulator and swap tests, and follow the fault through electrodes and front ends, SpO2 optics, NIBP pneumatics, pressure transducers, gas paths, power, display and the network to the part that has actually failed - and then return the monitor to service with the verification, leakage tests and records the repair requires. - [MRI Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/mri-l2/) — Level 2; 10 lessons, 6 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep an MR scanner safe, cold and documented. Level 2 starts when it stops scanning or the radiologist rejects the images. This course teaches the engineer to read the error history before opening a cabinet, translate an artefact into the subsystem that made it, separate the scanner from the room it stands in, and prove the repair with the same test that found the fault - while leaving ramping, shimming and quench recovery to the specialists who own them. - [Neusoft NeuViz 16 and NeuViz 128 CT — Model Service](https://serviceengineer.academy/course/neusoft-neuviz/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed CT Service — Level 1 and ideally Level 2. It takes the NeuViz 16 and NeuViz 128 apart on paper: the stator and rotor control boards, the CAN network of units and its UCOM interfaces, the HV generator variants, the A-plane collimator and compensator, the DMS detector and its data path across the slip ring, the couch and the console. It then covers the calibration matrices and what each calibration proves, planned maintenance, fault-finding by process stage from initialisation to image quality using the gantry display codes, board LEDs and the error log viewer, and a full return to service after repair. Independent course: not affiliated with or endorsed by Neusoft Medical Systems or Philips. Neusoft, NeuViz, Philips and other names are trademarks of their respective owners. - [Newport HT70 Ventilators — Model Service](https://serviceengineer.academy/course/newport-ht70/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ventilator Service — Level 1 and ideally Level 2. It takes the Newport HT70 family apart on paper: the twin micro-piston pump, the manifold valves and the exhalation drive, the transducers, oxygen added at the intake, the Power Pac and internal backup battery; the Circuit Check, Quick Check and the full Operational Verification Procedure with an analyser; the 24-month replacement set and battery care; fault-finding from alarm to assembly; and repair with calibration, software and release handled correctly. Independent course: not affiliated with or endorsed by Newport Medical Instruments, Covidien or Medtronic. Newport and HT70 are trademarks of their owner; other names are trademarks of their respective owners. - [Nipro Surdial Hemodialysis Machine — Model Service](https://serviceengineer.academy/course/nipro-surdial/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Dialysis Equipment Service — Level 1. It takes the Nipro Surdial apart on paper: the hydraulic circuit by component symbol, the viscous chambers and bellowphragm pumps, the blood-side modules, the power box and the ten maintenance modes; the checks with independent instruments and the values the manufacturer gives; disinfection, wear parts and counters; fault-finding from error number to component; and a full return to service with settings, software, calibration and electrical safety handled correctly. Independent course: not affiliated with or endorsed by Nipro. Nipro and Surdial are trademarks of their owner; other names are trademarks of their respective owners. - [Nihon Kohden BSM-6000 Bedside Monitors — Model Service](https://serviceengineer.academy/course/nk-bsm/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Patient Monitor Service — Level 1. It takes the BSM-6301, BSM-6501 and BSM-6701 apart on paper: main units, input units and the boards that carry each parameter, the built-in diagnostic and NIBP checks and what each one proves, the annual inspection, batteries and pneumatics, fault-finding from screen message to replaceable board, and a full return to service with settings, software and safety handled correctly. Independent course: not affiliated with or endorsed by Nihon Kohden. Nihon Kohden, BSM, Life Scope and Vismo are trademarks of their owner; other names are trademarks of their respective owners. - [Nihon Kohden TEC-5600 Cardiolife Defibrillator — Model Service](https://serviceengineer.academy/course/nk-tec-5600/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed the Level 1 defibrillator course. It takes the TEC-5600 series apart on paper: the five models and their options, the MOTHER board, HV DRIVE board and biphasic HV unit, the paddle holder test load, battery, recorder and parameter unit, what the self-tests, the basic check and the status indicator really prove, the monthly and yearly analyser checks, maintenance of batteries and accessories, fault-finding from error code letter to replaceable board, and a return to service with data, software, adjustments and electrical safety handled correctly. Independent course: not affiliated with or endorsed by Nihon Kohden. Nihon Kohden and Cardiolife are trademarks of their owner; other names are trademarks of their respective owners. - [Ophthalmic Equipment Service — Level 1](https://serviceengineer.academy/course/ophth-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A lamp with the filament in the wrong place, a fingerprint on a measurement window, a dust ball in a tonometer, a worn joystick, two programs fighting for one camera - most ophthalmic downtime starts with small things that a well-trained engineer finds in minutes. This course teaches the engineer who looks after an eye clinic how its instruments work, how to keep them safe and accurate, and where the specialist's work begins. - [Ophthalmic Equipment Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/ophth-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep an eye clinic's instruments safe, clean and verified. Level 2 starts when the right lamp, a clean window and a reseated cable have not helped. This course teaches the engineer to turn a clinician's complaint into a repeatable test on a test eye or target, place the fault on the instrument's block map, and follow it through illumination, optics and mechanics, refraction, keratometry and tonometry modules, biometers and OCT scanners, treatment lasers, cameras, PCs and data links to the assembly that has actually failed - and then return the instrument to service with the checks, safety tests and records that prove it, while knowing exactly what belongs to the manufacturer. - [DICOM, PACS and Networks for Service Engineers](https://serviceengineer.academy/course/pacs-dicom/) — General; 6 lessons, 3 h, certificate; $79 per engineer, team of 5 $290. A CT that sends three images at a time because the wall socket only runs at 100 megabits. A CR reader that stops sending because someone in IT changed the workstation's address. Three X-ray rooms with the same IP address, and a leg image on a chest cassette. Imaging equipment no longer ends at the detector: it ends when the right images of the right patient are safely in the archive and on the radiologist's screen. This course gives the service engineer the working knowledge of DICOM, PACS, worklists and hospital networks needed to configure a modality, prove where a transfer fails, talk to hospital IT on equal terms, protect patient data and return the system to service with evidence. It is built on real resolved cases from CT, MRI, X-ray, CR, mammography, ultrasound, workstations and DICOM printers. - [DICOM, PACS and Networks — Level 2: Fault-Finding](https://serviceengineer.academy/course/pacs-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. The general course taught you to configure a DICOM node, test it layer by layer and return a link to service. Level 2 starts where those tests all pass and the problem stays. This course teaches the engineer to collect evidence from the modality, the PACS and the workstation at the same moment, read an association reject or a status code for what it really says, follow a worklist entry or a study through every system it touches, find the network fault that ping cannot see, recover a workstation or a database without losing images, and hand the system back with proof that every study is complete and under the right patient. - [Penlon Prima SP2 and SP3 Anaesthetic Machines — Model Service](https://serviceengineer.academy/course/penlon-prima-sp/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Anaesthesia Machine Service — Level 1. The Prima SP2 and SP3 are mechanical machines: gas blocks with their own regulators, a pneumatic gas delivery switch, a gear-linked hypoxic guard, glass flowtubes and a Selectatec-type backbar, with the absorber, ventilator and oxygen monitor as separate units. The course takes that platform apart on paper, runs the high and low pressure leak tests, the oxygen failure and hypoxic guard tests in the right order, follows the six-monthly, annual, two-year and four-year kits, finds faults by section of the gas path and returns the machine to service with the protections proven, not assumed. Independent course: not affiliated with or endorsed by Penlon. Penlon, Prima, Sigma Delta, Safelock and AV-S are trademarks of their owner; Selectatec, Bodok and other names are trademarks of their respective owners. - [Philips Efficia DFM100 Defibrillator/Monitor — Model Service](https://serviceengineer.academy/course/philips-dfm100/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Defibrillator and ECG Service — Level 1. It takes the Efficia DFM100 apart on paper: the Processor and SOM PCAs, the Therapy PCA with its capacitor and resistor module, the therapy port, measurement module, printer, power supply and battery, and the SpO2, NBP and EtCO2 options; what the hourly, daily and weekly automated tests and the Ready For Use indicator prove and what they never touch; the Operational Check and the manufacturer's performance verification with an analyser; battery, paddles, cables, printer and EtCO2 maintenance; fault-finding from the technical alarm and the hardware error log group to one accessory or assembly; and a safe repair with capacitor discharge, correct handling of serial number, options, software and configuration, and release only after the required tests. Independent course: not affiliated with or endorsed by Philips. Philips, Efficia, SMART Biphasic and HeartStart are trademarks of Koninklijke Philips N.V.; other names are trademarks of their respective owners. - [Philips IntelliVue MX400–MX550 Patient Monitors — Model Service](https://serviceengineer.academy/course/philips-intellivue-mx/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Patient Monitor Service — Level 1. It takes the IntelliVue MX400, MX450, MX500 and MX550 apart on paper: the main unit and its boards, the MMS, extensions, plug-in modules and X2 on the measurement link, the network and central station, the safety, system and performance tests and their acceptance values, cleaning and battery care, fault-finding from LEDs, boot sequence and INOPs to one replaceable part, and a return to service with serial number, configuration, software and electrical safety handled correctly. Independent course: not affiliated with or endorsed by Philips. Philips and IntelliVue are trademarks of Koninklijke Philips N.V.; Masimo, Nellcor, Microstream and other names are trademarks of their respective owners. - [Physio-Control LIFEPAK 1000 AED — Model Service](https://serviceengineer.academy/course/physio-lifepak-1000/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Defibrillator and ECG Service — Level 1. It takes the LIFEPAK 1000 apart on paper: its modes and options, the analog and digital boards, the capacitor and dump path, the patient connector, the lithium battery pak and the readiness indicator; the closed-case performance inspection with energy, charge time, electrode detection, ECG and leakage; battery and electrode logistics for public-access programmes; fault-finding from readiness symbol and service log code to the right decision; and a clean return to service with the line between field work and factory service drawn where the manufacturer draws it. Independent course: not affiliated with or endorsed by Physio-Control, Stryker or Medtronic. LIFEPAK, QUIK-COMBO, REDI-PAK, CODE-STAT and other names are trademarks of their respective owners. - [Planned Maintenance Programme for Medical Equipment](https://serviceengineer.academy/course/pm-programme/) — General; 6 lessons, 3 h, certificate; $79 per engineer, team of 5 $290. As head of a biomedical engineering department or a service company manager, you answer for every device in the hospital: is it on the list, how often is it checked, who does the work, and can you prove it was done. This course shows how to build that programme step by step from open WHO guidance and the US CMS memo on alternate equipment management: a clean inventory, risk-based classification, manufacturer-based procedures, a schedule that fits your engineer-hours, records that satisfy an auditor, and a quarterly report management can act on. - [Medical Imagers and Film Printers — Level 1](https://serviceengineer.academy/course/printers-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A film loaded upside down, an expired box, a dirty roller, a filter nobody changed, a modality that sends the wrong film size — most imager downtime starts with something cheap and checkable. This course teaches the engineer who looks after dry and laser imagers to understand how the film is picked, exposed and developed, to read artefacts and error groups, to sort out DICOM print settings, and to carry out PM and QC before handing the printer back. - [Medical Imagers and Film Printers — Level 2: Fault-Finding](https://serviceengineer.academy/course/printers-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to clean, load, calibrate and hand back a film printer. Level 2 starts when the fault survives all of that. This course teaches the engineer to read the error history and counters for the first cause, to split a fault between film, transport, image writing, processing, electronics and the sending host with one cheap test at a time, and to follow it to the assembly that has really failed: pick-up, rollers and sensors, thermal head, laser and polygon, heated drum, densitometer, power supply, controller and storage, network and DICOM settings. It ends with the return to service: the measurements, test prints, constancy checks and records that prove the imager is fit to print again. - [Medical Equipment Service Budget](https://serviceengineer.academy/course/service-budget/) — General; 6 lessons, 3 h, certificate; $79 per engineer, team of 5 $290. As head of a biomedical engineering department or a service company manager, you are asked every year what the equipment service budget buys, why it grows and what happens if it is cut. This course shows how to answer with data, using open WHO guidance from the Medical device technical series: a cost base built from the inventory and work orders, the cost of service ratio, service offers compared on equal scope, staff cost built from engineer-hours, a scored replacement list with total cost of ownership, and a budget that is presented in terms of risk, uptime, compliance and money and controlled month by month. - [Siemens Clinitek Advantus and Status+ Urine Chemistry Analysers — Model Service](https://serviceengineer.academy/course/siemens-clinitek/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Lab Analyser Service — Level 1. It takes two urine strip readers apart on paper: the semi-automated Clinitek Advantus with its push bar, moving table, two scanning readheads and calibration chip, and the single-strip Clinitek Status and Status+ with their LED and CCD optics and white calibration bar on the test table. You learn what each start-up, reference, diagnostic, check-cassette and hard-standard check proves, how to care for platforms and test tables without damaging the reference, how to go from an error code to the right part or user correction, and how to return an instrument to service with configuration, release checks and laboratory controls handled properly. Independent course: not affiliated with or endorsed by Siemens Healthineers. Siemens Healthineers, Clinitek, Clinitek Advantus, Clinitek Status, Multistix and Chek-Stix are trademarks of their owners; other names are trademarks of their respective owners. - [SNIBE Maglumi 2000 Plus Chemiluminescence Immunoassay Analyser — Model Service](https://serviceengineer.academy/course/snibe-maglumi-2000-plus/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Lab Analyser Service — Level 1 and preferably Level 2. It follows a cuvette through the Maglumi 2000 Plus from stacker to waste bag, names the module, pump and control board behind each step, and turns the operator documentation into an engineer's method: start-up and temperature checks, the BGW and light check read as one picture, calibration and QC as release evidence, the daily, weekly and monthly programme, error codes grouped by block, halts and cuvette jams, pipetting, washing, light and LIS faults, and a safe return to service after repair. Independent course: not affiliated with or endorsed by Shenzhen New Industries Biomedical Engineering (Snibe). SNIBE and MAGLUMI are trademarks of their owner; other names are trademarks of their respective owners. - [SonoScape S-Series Portable Ultrasound — Model Service](https://serviceengineer.academy/course/sonoscape-s-series/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ultrasound Service — Level 1 and, ideally, Ultrasound Probes. It takes the SonoScape S6 apart on paper as the reference for the S-series portables: its front-end boards and PC back end and the USB link between them, the start-up sequence read as a diagnostic ladder, the built-in system tests and key simulation, planned maintenance with disinfectant compatibility and the electrical safety test of the whole system, fault-finding by start-up stage and by artefact, board and disk replacement with what each one requires, software reload and option keys at procedure level, and a full return to service. Independent course: not affiliated with or endorsed by SonoScape Medical. SonoScape is a trademark of its owner. - [Steriliser Service — Level 1](https://serviceengineer.academy/course/steril-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. The display says 'cycle complete' whether or not steam reached the inside of the pack. Air left in the chamber, a door seal that leaks under vacuum, a drifting temperature sensor or bad feed water can all give a cycle that looks normal and a load that is not sterile. This course teaches the engineer who maintains sterilisers to understand what the machine is really doing, keep it safe, test it properly and return it to service with evidence. - [Steriliser Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/steril-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you what a steriliser does, how to keep it safe and how to read its daily tests. Level 2 starts when the tests fail and the obvious checks are done. This course teaches the engineer to read the cycle record phase by phase, use the pressure-temperature curve and the alarm history to place the fault, and follow it through the steam generator and water, the vacuum system, the door and chamber, the control and sensors, low-temperature and benchtop units and washer-disinfectors to the assembly that has actually failed - and then return the machine to service with the tests, records and decisions that prove it fit. - [Sumitomo MRI Cryocooler Service — Model Service](https://serviceengineer.academy/course/sumitomo-mri-cryo/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed MRI Service — Level 1. It takes apart the Sumitomo (SHI) cryocooler found on magnets from several MRI manufacturers: the CSA-71A air-cooled and CSW-71D water-cooled compressors, their flex lines and RDK-408 series cold heads. You learn the gas and oil path and the protective devices, the readings that show a drifting system, the adsorber change and a clean helium top-up, the fault-finding order for trips, pressure faults and knocking heads, and how a cold head exchange is prepared, verified on the magnet over the following days and documented. Independent course: not affiliated with or endorsed by Sumitomo Heavy Industries or any MRI manufacturer. Sumitomo, SHI and the model names mentioned are trademarks of their owners. - [Sysmex XP-300 Haematology Analyser — Model Service](https://serviceengineer.academy/course/sysmex-xp300/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Lab Analyser Service — Level 1 and ideally Level 2. It takes the XP-300 apart on paper: the sample rotor valve and the dilution paths, the compressor, regulator and the working pressure and vacuum, the impedance detectors and the HGB cell, the boards and what each one does; the start-up, background and status checks and what each proves; QC and calibration read with the analyser's architecture in mind; the manufacturer's maintenance schedule and the engineer's checks it leaves out; fault-finding from error code and sub code to one assembly; and repair with the adjustments in the right order and a documented return to service. Independent course: not affiliated with or endorsed by Sysmex. Sysmex, XP-300, KX-21, CELLPACK, STROMATOLYSER, CELLCLEAN, EIGHTCHECK, CELLCHECK and SNCS are trademarks of their owner; other names are trademarks of their respective owners. - [Ventilator Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/vent-l2/) — Level 2; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep a ventilator safe, maintained and verified. Level 2 starts when it fails anyway: a self-test step that will not pass, a volume that reads low, a PEEP that will not hold, a machine that reboots on battery. This course teaches the engineer to read the event log and the failed test step, place the fault on the gas path or in the electronics, and follow it through the supply, the blender or turbine, the sensors, the valves and the power chain to the module that has actually failed - then prove the repair with the manufacturer's calibrations, an independent analyser and a clear record. - [Infant Flow SiPAP Neonatal CPAP System — Model Service](https://serviceengineer.academy/course/vyaire-infant-flow-sipap/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ventilator Service — Level 1, and ideally Level 2. It takes the Infant Flow SiPAP driver apart on paper: the gas module with its blender, flowmeters, vent, dump and pop-off valves, the valve/sensor and main processor boards, the patient trigger and abdominal sensor, power and battery; the power-up check, the diagnostics screen and calibrations; performance and alarm checks with reference instruments and the internal oxygen leak test; the annual, two-year and five-year maintenance items; fault-finding from whistle, alarm or error code to the replaceable assembly; and a full return to service with calibration, firmware and electrical safety handled correctly. Independent course: not affiliated with or endorsed by Vyaire Medical, CareFusion, VIASYS Healthcare or any later owner of the product line. Infant Flow and SiPAP are trademarks of their owner; other names are trademarks of their respective owners. - [Vyaire (Bird) VELA Ventilator — Model Service](https://serviceengineer.academy/course/vyaire-vela/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Ventilator Service — Level 1 and ideally Level 2. It takes the VELA apart on paper: the turbine with its speed encoder and differential transducer, the solenoid-and-orifice oxygen blender, the exhalation valve and variable-orifice flow sensor, the mechanical safety valves, the power PCB, battery tray and main board generations; the user verification test, the transducer calibrations and the operational verification with an analyser and test lung; the one-year PM kit, batteries, oxygen cell and cleaning; fault-finding from failed test or alarm to assembly; and repair with turbine data, software and release handled correctly. Independent course: not affiliated with or endorsed by Vyaire Medical, Bird, Cardinal Health, CareFusion or VIASYS. VELA and Bird are trademarks of their owner; other names are trademarks of their respective owners. - [X-ray Service — Level 1](https://serviceengineer.academy/course/xray-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. A loose earth, a cracked limit switch, a detector calibrated with the grid in place, a workstation whose IP address someone changed — most X-ray downtime starts with something small that nobody checked in order. This course teaches the engineer who maintains radiography rooms, mobile units and C-arms to work safely around radiation and high voltage, to understand the image chain from generator to PACS, and to carry out planned maintenance and fault-finding by subsystem. - [X-ray Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/xray-l2/) — Level 2; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to keep an X-ray room safe, measured and maintained. Level 2 starts when it stops anyway. This course teaches the engineer to read the error list and the exposure history for the first cause rather than the loudest message, place the fault in the exposure sequence, and follow it through the supply, the generator, the tube, the collimator and AEC, the detector, the stands and the software to the subsystem that has actually failed - and then return the room to service with the tests, dose checks and records that prove it. - [ZOLL R Series Defibrillators — Model Service](https://serviceengineer.academy/course/zoll-r-series/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Defibrillator and ECG Service — Level 1. It takes the R Series ALS, Plus and BLS apart on paper: the system brick with its digital and analog boards and the PD engine with its capacitor, the OneStep cable and electrode family, the SurePower battery and charger, the printer and the monitoring options; what the Code Readiness system tests and what it leaves to you; the annual checkout with an analyser and what each result means on this waveform; battery and accessory maintenance; fault-finding from the message on the screen to an accessory, a setting or a replaceable assembly; and a safe repair and return to service with data, software and configuration handled correctly. Independent course: not affiliated with or endorsed by ZOLL Medical Corporation. ZOLL, R Series, OneStep, SurePower, Code-Ready and CodeNet are trademarks of their owner; other names are trademarks of their respective owners. - [ZOLL X Series Monitor/Defibrillator — Model Service](https://serviceengineer.academy/course/zoll-x-series/) — Model; 5 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. A model course for engineers who have passed Defibrillator and ECG Service — Level 1. It takes the X Series and X Series Advanced apart on paper: the monitor board with its three processors and power system, the two-board defibrillator module and the capacitor, the NIBP, EtCO2, SpO2, IBP and temperature options, the printer, the communications carrier and the SurePower battery; what the Ready For Use indicator and the readiness test prove and what they leave to you; the 25-step annual test sequence with an analyser and simulators and the acceptance values that go with it; battery, cable and accessory upkeep; fault-finding from the message on the screen to an accessory, a setting or one module; and a safe repair and return to service, with restricted parts, data, software and electrical safety handled correctly. Independent course: not affiliated with or endorsed by ZOLL Medical Corporation. ZOLL, X Series, SurePower and Rectilinear Biphasic are trademarks of their owner; Masimo, Rainbow, Oridion and Microstream are trademarks of their respective owners. - [Medicine for Engineers](https://serviceengineer.academy/course/med-eng/) — General; 8 lessons, 4 h, certificate; $49 per engineer, team of 5 $190. Every device you repair measures or supports something in a human body. If you do not know what that something is, you cannot tell a fault from a patient, a misleading reading from a real one, or an urgent call from a loud one. This course gives the service engineer the medicine behind the equipment: how a hospital works, what images show, what the heart, lungs and blood tell the clinician, why anaesthesia and intensive care leave no time for failure, how not to carry infection, and how to turn a clinician's complaint into a technical question you can test. - [Physics of Medical Equipment](https://serviceengineer.academy/course/physics/) — General; 10 lessons, 5 h, certificate; $49 per engineer, team of 5 $190. A noisy MRI image, a chiller alarm, a dead line on an ultrasound picture, a leak test that fails by a few millilitres: each of these is physics before it is a part number. This course takes the physics a service engineer actually uses — electricity and fields, waves and radiation, sound, magnetic resonance, cryogenics, gases, light, heat and measurement — and explains each through the machine it lives in and the symptom it produces when something goes wrong. - [Electrical Safety for Medical Equipment](https://serviceengineer.academy/course/esafety/) — General; 6 lessons, 3 h, certificate; $79 per engineer, team of 5 $290. Every repaired device goes back to a patient. Electrical safety testing is the last line between your repair and that patient — and it is also the test most often done as a formality. This course explains why the limits exist, how the analyzer measures, and how to test and document properly after repair and at every PM. - [Pneumatics and Medical Gases — Repair Fundamentals](https://serviceengineer.academy/course/pneumatics/) — Repair fundamentals; 8 lessons, 5 h, certificate; $99 per engineer, team of 5 $390. Ventilators, anaesthesia workstations, suction units, concentrators, dental chairs and laboratory analysers are built from the same pneumatic parts: regulators, valves, sensors, seals and the gas supply that feeds them. This course teaches the trade they share - how each part works, how it fails, how to test it on the bench, how to find a leak by method rather than luck, and how to repair and prove the repair without creating an oxygen hazard. - [Electronics and Power Supplies — Repair Fundamentals](https://serviceengineer.academy/course/electronics/) — Repair fundamentals; 10 lessons, 6 h, certificate; $99 per engineer, team of 5 $390. Monitors, ultrasound systems, infusion pumps, ventilators and X-ray generators share the same electronics: switch-mode supplies, regulators, batteries, processor boards, buses, cables and connectors. This course teaches the trade they have in common — working safely on the bench, reading schematics, using instruments correctly, and finding the failed board and the failed component by method rather than by swapping parts until the fault goes away. - [MRI Service — Level 1](https://serviceengineer.academy/course/mri-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. A healthy MRI magnet loses almost no helium: the cold head turns the boil-off back into liquid. When the cold head, the compressor or the chiller stops, the level starts to fall — and nobody notices until it is expensive. This course teaches the engineer who services the scanner to see it coming. - [CT Service — Level 1](https://serviceengineer.academy/course/ct-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Air conditioning, dirty filters, a skipped air calibration, a slip ring nobody cleaned — most CT failures start with something cheap that nobody checked. This course teaches the engineer who maintains a CT scanner to keep it safe, calibrated and running. - [Ultrasound Service — Level 1](https://serviceengineer.academy/course/us-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. Probes are dropped, bent, soaked in the wrong disinfectant and plugged in hot. This course teaches the engineer to test probes, judge image quality, maintain the system and tell a probe fault from a system fault in minutes. - [Ultrasound Service — Level 2: Fault-Finding](https://serviceengineer.academy/course/us-l2/) — Level 2; 10 lessons, 6 h, certificate; $149 per engineer, team of 5 $590. Level 1 taught you to test a probe. Level 2 starts when the probe is innocent. This course teaches the engineer to move a fault before touching a screwdriver, read the logs and built-in tests, and follow the symptom through the front end, the beamformer, the power chain and the PC to the one module that has failed - then prove the repair with a phantom and a safety test. - [Ultrasound Probes — Testing, Diagnosis and Repair Decisions](https://serviceengineer.academy/course/us-probes/) — Probe repair; 8 lessons, 5 h, certificate; $149 per engineer, team of 5 $590. Probes are dropped, crushed, soaked and bitten, and they cost as much as a car. This course takes the engineer inside the probe: how it is built, how each layer fails, how to test it with and without a probe tester, how to clear endocavity and TEE probes electrically, how mechanical 4D and TEE probes fail, and how to decide - on evidence - between repair, replacement and withdrawal. - [Ventilator Service — Level 1](https://serviceengineer.academy/course/vent-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. The self-test checks the machine against itself. Only an independent gas-flow analyzer on a test lung tells you what the patient would actually receive. This course teaches the engineer who maintains ICU ventilators to keep them safe: gas supply, pneumatics, the PM kit, and the verification that must follow every repair. - [Anaesthesia Workstation Service — Level 1](https://serviceengineer.academy/course/anes-l1/) — Level 1; 8 lessons, 4 h, certificate; $149 per engineer, team of 5 $590. An anaesthesia workstation is a gas system, a ventilator, a monitor and a set of safety interlocks in one cart. This course teaches the engineer to follow the gas path, run leak and checkout tests properly, maintain the machine and verify it before it goes back to theatre. - [Patient Monitor Service — Level 1](https://serviceengineer.academy/course/mon-l1/) — Level 1; 6 lessons, 3 h, certificate; $99 per engineer, team of 5 $390. ECG, SpO2, NIBP, IBP, temperature, CO2 — each parameter fails in its own way, and most failures are accessories. This course teaches the engineer to test every parameter with a simulator, separate accessory faults from module faults and maintain monitors to a standard that survives an audit. ## SE AI — troubleshooting assistant - [SE AI](https://serviceengineer.academy/ai/): describe a fault on medical equipment and get a step-by-step check plan grounded in real repair cases and service documentation; it does not invent part numbers. 3 free questions after sign-up; included for 3 months with any course; or $12 a month. - [SE AI vs ChatGPT](https://serviceengineer.academy/ai/vs-chatgpt/): how a troubleshooting assistant grounded in service manuals and field cases differs from general-purpose AI, and when to use which. - [Connect SE AI to Claude or ChatGPT (MCP)](https://serviceengineer.academy/ai/connect/): MCP server https://api.serviceengineer.academy/mcp ## For companies - [Training for teams](https://serviceengineer.academy/teams/): one table of every engineer's courses, exam scores and certificates; training records as PDF or CSV for JCI and ISO audits; assign courses with due dates. 5 seats for the price of 4. Example company: https://api.serviceengineer.academy/training?demo=1 - [How to document the competency of biomedical engineers](https://serviceengineer.academy/guides/document-biomedical-engineer-competency/): what auditors look for and a simple training record that holds up, with what ISO 13485 clause 6.2 and ISO 9001 clause 7.2 expect and a CSV template - [For heads of service departments](https://serviceengineer.academy/managers/): courses and free guides for heads of biomedical engineering departments and service managers - [Planned Maintenance Programme for Medical Equipment](https://serviceengineer.academy/course/pm-programme/): course for managers on inventory, WHO-style risk classification, procedures, scheduling, completion indicators and audit - [Medical Equipment Service Budget](https://serviceengineer.academy/course/service-budget/): course for managers on budget lines, cost data, comparing service contracts on equal scope, staffing cost, replacement planning and budget control - [Factory vs independent service training](https://serviceengineer.academy/guides/factory-vs-independent-service-training/): when engineers need manufacturer training, when vendor-neutral courses are enough, and how to combine both - [How to run training for a team of service engineers](https://serviceengineer.academy/guides/team-training-service-engineers/): skills matrix, course assignment, assessment, records and refresher dates ## Free reference - [Fault library](https://serviceengineer.academy/faults/): real fault cases by equipment type - [Equipment and models](https://serviceengineer.academy/library/): how equipment works, by model - [All courses](https://serviceengineer.academy/courses/) - [Programs](https://serviceengineer.academy/programs/)