Academy / Courses / GE Mac-Lab and CardioLab Hemodynamic Recording Systems — Model Service
ModelCertificate course

GE Mac-Lab and CardioLab Hemodynamic Recording Systems — Model Service

Signal checks, backups, network and database faults, recovery and safe return to service on Mac-Lab, CardioLab and ComboLab 6.5.6

A model course for engineers who have passed Angiography and C-arm Service — Level 1. It takes the Mac-Lab, CardioLab and ComboLab recording systems on software 6.5.6 apart on paper: TRAMNet and the CardioLab II Plus amplifier, the acquisition computer and its boards, the IEB and UPS, review stations, the Centricity Cardiology INW server and the DICOM and HL7 links to the X-ray system and the CVIS. You learn the manufacturer's checkout with a patient simulator, electrical safety of a medical electrical system with intracardiac connections, backups that really restore, fault-finding from signal noise to domain and replication faults, and recovery and return to service without losing patient data. Independent course: not affiliated with or endorsed by GE HealthCare. Mac-Lab, CardioLab, Centricity, TRAM and TRAMNet are trademarks of their owner; other names are trademarks of their respective owners.

Not started
01

The X-ray works and the case cannot start. This course is about the recorder next to it.

  • Mac-Lab and CardioLab systems sit in almost every GE catheterisation and EP lab, yet engineers meet them with an X-ray background and a service manual that is mostly Windows, SQL and domain procedures.
  • Typical calls end with a TRAMNet adapter, an amplifier or a whole computer replaced while the real cause was an IP address clash, a dirty fibre, an electrode of the wrong type, a clock that drifted from the domain or an archive job scheduled on top of another.
  • Repairs are released after a quick look at the screen: no simulator checkout, no leakage on the intracardiac front end, no restore test of the backups, and sometimes a reimage that wiped the very disk holding the site's lists and options.
02

After the course you can

01Identify a Mac-Lab, CardioLab or ComboLab configuration, its acquisition hardware, computer boards, IEB, UPS, server and interfaces, and know where studies, backups and settings live.
02Run the manufacturer's checkout with a patient simulator, check pressure zero and calibration, time, network, DICOM and database links, and measure electrical safety on the patient-connected units of the system.
03Perform the annual maintenance: inspection and cleaning, database maintenance and archive schedules, backup restore tests, RAID and storage health, validated antivirus and patches, UPS and records.
04Locate faults in signals, pressure, TRAM and amplifier links, acquisition-to-review messaging, domain, replication, DICOM, HL7, video, printing and option licences using the manual's checks and logs.
05Prepare a repair without data loss, replace assemblies at procedure level, support a recovery done to the manufacturer's procedure by authorised personnel, and release the system only after checkout, safety tests and documentation.
03

Curriculum

01The platform: acquisition hardware, workstations, the INW network and software 6.5.6
Identify which Mac-Lab, CardioLab or ComboLab configuration is in front of you, trace every patient signal from the TRAM or amplifier to the acquisition computer, and know which computer, server and interface holds what before you touch anything.
free
22 min
02Checks: signals with a simulator, pressure zero and calibration, time, network, database and electrical safety
Run the manufacturer's checkout on a Mac-Lab, CardioLab or ComboLab after any service, prove every signal path with a patient simulator, confirm time, network and database links, and measure electrical safety on the patient-connected parts in the sense of an IEC 60601-1 medical electrical system.
22 min
03Maintenance: annual PM, backups and database maintenance, storage health, validated antivirus and patches, UPS, cleaning and records
Plan and perform the annual maintenance of a Mac-Lab/CardioLab installation, prove that its backups can actually be restored, keep disks and storage healthy, keep the software inside the manufacturer's validated configuration, and leave a record the next engineer can trust.
21 min
04Troubleshooting: noisy or missing signals, pressure faults, acquisition-to-review links, database and network faults, printing, licence and startup errors
Take a Mac-Lab or CardioLab complaint from the user's words to the faulty segment: patient, cable, TRAM or amplifier, computer, network, server or configuration, using the manufacturer's checks and logs, without losing data or touching what you are not authorised to change.
24 min
05Repair and return to service: hardware replacement, recovery and software restore, verification, documentation and cybersecurity
Prepare for a repair so no patient data is lost, replace computer, IEB, UPS, video and interface assemblies at procedure level, take part in an acquisition or server recovery under the manufacturer's procedure, and release the system only after the checkout, safety tests and records prove it.
23 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
GE Mac-Lab and CardioLab Hemodynamic Recording Systems — Model Service (Endorsement)
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Engineers who have completed Angiography and C-arm Service — Level 1 or have equivalent experience
  • Hospital biomedical teams and independent service companies maintaining GE Mac-Lab and CardioLab recording systems in catheterisation and EP labs

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this GE HealthCare training?

No. It is an independent course, not affiliated with or endorsed by GE HealthCare. Mac-Lab, CardioLab, Centricity, TRAM and TRAMNet are trademarks of their owner, and other names are trademarks of their respective owners. The course does not replace the manufacturer's procedures and does not grant authorisation, passwords, licence keys or access to service software.

Which software version does it cover?

Version 6.5.6 on HP z600 and xw8400 acquisition computers and G4, G5 and G6 INW servers, as described in the manufacturer's INW service manual for that version. Older 6.5 systems on xw8000 and xw8200 computers and newer releases use their own documentation; much of the method transfers, the procedures and parts do not.

Do I need the service manual?

You should have the manufacturer's service, installation and operator documentation and the security guide for the system you work on. The course explains and orders the work; exact procedures, part numbers, media and acceptance values come from that documentation.

Does it teach software reinstallation and options?

Only at procedure level: who decides, what to back up, what to protect and what to check before and after. Reimaging, restores and options are done by authorised personnel with the manufacturer's media and keys, following the manufacturer's procedure.

How does it relate to the other angiography courses?

Angiography Level 1 and Level 2 cover the X-ray side of the lab, and the GE Brivo OEC 850 course a mobile C-arm. This course covers the recording and information system beside the X-ray equipment. DICOM and networking basics are in the DICOM, PACS and Networks course and are only applied here.

What does the certificate say?

GE Mac-Lab and CardioLab Hemodynamic Recording Systems — Model Service (Endorsement), with your name, the hours, the date and your exam score, a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.