Academy / Courses / Mammography Service — Level 1
Level 1Certificate course

Mammography Service — Level 1

Compression, detectors, dose and quality control

Part of the program: Mammography Service Engineer — program (8 h) →

A paddle that creeps, a thickness reading a centimetre out, a detector calibrated cold, a grid that sticks — in mammography small faults cost image quality and dose for every woman screened. This course teaches the engineer who maintains a mammography unit what makes it different from general X-ray and how to keep it safe, calibrated and fit for screening.

Not started
01

A mammogram looks for specks smaller than a millimetre. Small faults hide them.

  • Mammography is screening of mostly healthy women: a small loss of contrast or a small rise in dose matters across thousands of examinations.
  • Compression, low-kV beams, sensitive detectors and strict QC programmes make a mammography unit different from a general X-ray room, and general X-ray habits do not always transfer.
  • Many call-outs are solved by understanding the system — settings, environment, calibration routines and the workstation — rather than by replacing expensive parts.
02

After the course you can

01Name the blocks of a mammography system and explain why low kV, special targets and filters, small foci, the grid and AEC are built as they are.
02Check compression force and thickness, paddles, C-arm motion and every way of releasing a patient, and never accept a bypassed protection.
03Read tube, generator and AEC errors, walk the chain of exposure permissions, and know which calibrations belong to authorised service.
04Protect the detector: room climate, cooling, correct offset and gain calibration, and tell calibration artefacts from hardware faults, including in CR rooms.
05Understand the QC programme, phantoms and mean glandular dose at principle level, and the division of work between radiographer, engineer and medical physicist.
06Fault-find by subsystem using logs, recognise common artefact sources, and return a unit to service with the right checks and a written report.
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Mammography Service — Level 1: Compression, detectors, dose and quality control
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Hospital biomedical / clinical engineering teams
  • Field engineers in independent service companies

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's procedures or grant authorisation or access to service software.

Does it replace the medical physicist?

No. The course explains the QC and dose tests so that you can support them and understand the results; formal performance and dose assessment remains with the medical physicist or accredited organisation under your national rules.