Early access · courses are being reviewed by field engineers
Service EngineerAcademy
Academy / Courses / Nihon Kohden BSM-6000 Bedside Monitors — Model Service
ModelCertificate course

Nihon Kohden BSM-6000 Bedside Monitors — Model Service

Diagnostics, NIBP checks, maintenance and fault-finding on the BSM-6301, 6501 and 6701

Part of the program: Patient Monitor Service Engineer — full program (10 h) →

A model course for engineers who have passed Patient Monitor Service — Level 1. It takes the BSM-6301, BSM-6501 and BSM-6701 apart on paper: main units, input units and the boards that carry each parameter, the built-in diagnostic and NIBP checks and what each one proves, the annual inspection, batteries and pneumatics, fault-finding from screen message to replaceable board, and a full return to service with settings, software and safety handled correctly. Independent course: not affiliated with or endorsed by Nihon Kohden. Nihon Kohden, BSM, Life Scope and Vismo are trademarks of their owner; other names are trademarks of their respective owners.

Not started
01

You know how a monitor measures. This course is about where this one breaks.

  • BSM-6000 monitors are common in intensive care and theatres, and engineers meet them with a generic monitoring background and a service manual organised by procedure rather than by the fault in front of them.
  • Typical calls end with an input unit or a main board replaced while the real cause was a probe from the wrong SpO2 family, a leaking hose, a test set that leaked, a DIP switch on a new board or a bed never registered at the central station.
  • After a board change the touch is not calibrated, settings are not restored, the NIBP safety release is not tested and no leakage is measured, and the monitor goes back to the patient on trust.
02

After the course you can

01Identify the main unit, input unit and options, name the boards on the signal path of each parameter and know where settings, review data and software live.
02Run the diagnostic, manual and NIBP checks with a manometer and test volumes, verify every parameter and alarm with a simulator, and test leakage on every applied part.
03Perform the annual inspection to the manufacturer's check sheet, maintain batteries, NIBP pneumatics and accessories, and keep records that show trends.
04Locate faults in power, display, touch, ECG, SpO2, NIBP, IBP, input unit recognition and the network using screen messages, socket and unit swaps, the ping test and the error history.
05Prepare for repair with data backup and ESD and stored-energy precautions, replace boards and units at procedure level, handle software and settings correctly and release the monitor only after full verification.
03

Curriculum

01The BSM-6000 platform: main units, input units, boards and the signal path
Identify which BSM-6301, 6501 or 6701 and which input unit is in front of you, name the boards that carry each parameter from the patient socket to the screen, and know where settings, review data and software live before you open anything.
free
22 min
02Diagnostic and safety checks: the built-in tests, the parameter checks and leakage
Run the BSM-6000 diagnostic and manual checks in a sound order, verify every parameter and the NIBP pneumatics against the manufacturer's acceptance values, prove the alarms, and finish with an electrical safety test on every applied part.
25 min
03Periodic maintenance: inspection, batteries, NIBP pneumatics, accessories and records
Plan and perform the annual inspection of a BSM-6000 to the manufacturer's check sheet, maintain its batteries, NIBP pneumatics, recorder and accessories, clean it without damage and leave a record that proves what was done.
22 min
04Troubleshooting: power, display, parameters, input units, network and error history
Take a BSM-6000 fault from the complaint to a single replaceable board or accessory using the screen messages, the troubleshooting logic of the service manual, the manual checks and the error history.
25 min
05Disassembly, repair and return to service
Prepare a BSM-6000 for repair without losing data or causing damage, replace the main boards and units at procedure level, handle settings and software correctly, and prove the monitor safe and accurate before it goes back to a patient.
24 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Nihon Kohden BSM-6000 Bedside Monitors — Model Service (Endorsement)
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Engineers who have completed Patient Monitor Service — Level 1 or have equivalent experience
  • Hospital biomedical teams and independent service companies maintaining Nihon Kohden BSM-6000 monitors

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this Nihon Kohden training?

No. It is an independent course, not affiliated with or endorsed by Nihon Kohden. Nihon Kohden, BSM, Life Scope and Vismo are trademarks of their owner, and other names are trademarks of their respective owners. The course does not replace the manufacturer's procedures and does not grant authorisation, passwords or access to service software.

Do I need the service manual?

You should have the manufacturer's service and operator documentation for the monitor you work on. The course explains and orders the work; the exact procedures, acceptance values, switch settings and part codes come from the documentation for your revision.

Does it cover other Nihon Kohden monitors?

The course is written for the BSM-6301, BSM-6501 and BSM-6701 in their A and K variants. Much of the method transfers to other bedside monitors of the same maker, but their boards, checks and limits differ; use their own documentation.

Does it cover software upgrades and options?

Only at procedure level: who may do it, what to back up and what to check before and after. The steps themselves are the manufacturer's and are done by authorised personnel with the proper media.

What does the certificate say?

Nihon Kohden BSM-6000 Bedside Monitors — Model Service (Endorsement), with your name, the hours, the date and your exam score, a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.