Academy / Courses / Ophthalmic Equipment Service — Level 1
Level 1Certificate course

Ophthalmic Equipment Service — Level 1

Slit lamps, refraction, biometry, OCT and lasers

Part of the program: Ophthalmic Equipment Service Engineer — program (8 h) →

A lamp with the filament in the wrong place, a fingerprint on a measurement window, a dust ball in a tonometer, a worn joystick, two programs fighting for one camera - most ophthalmic downtime starts with small things that a well-trained engineer finds in minutes. This course teaches the engineer who looks after an eye clinic how its instruments work, how to keep them safe and accurate, and where the specialist's work begins.

Not started
01

Most eye clinic calls are not about lasers. They are about a lamp, a dusty window, a joystick or a USB cable.

  • An eye clinic is a queue: one auto-refractometer or tonometer that will not measure in the morning blocks every doctor behind it.
  • Ophthalmic instruments measure - refraction, pressure, axial length, retinal thickness - and a wrong number that nobody verified on a test eye can reach a prescription or a surgical decision.
  • Lasers, light hazard and eye-contact parts make the eye clinic a place where a well-meant shortcut can injure a patient or the engineer, yet the vendor-neutral basics are rarely taught.
02

After the course you can

01Name every instrument on the patient's route through an eye clinic, say what it measures or does, and identify its main assemblies.
02Work safely with light sources, treatment lasers and eye-contact parts: specified lamps and filters, laser classes and controlled areas, decontamination and electrical safety of combined systems.
03Replace lamps correctly, clean only the optics you may touch, check user-level alignment, and keep bases, joysticks and chin rests working.
04Explain how refractometers, tonometers, biometers and OCT units measure, verify them on test eyes and references, and trace wrong results to their cause.
05Fault-find cameras, PCs and data links, protect unique calibration data, and keep backups and exports working.
06Fault-find by symptom, perform Level 1 checks on a laser that will not fire and escalate correctly, run planned maintenance and return instruments to service with tests and records.
03

Curriculum

01The eye clinic: instruments and their main assemblies
Walk through an eye clinic, name every instrument a patient meets from reception to the laser room, say what each one measures or does, and point to its main assemblies and the parts a field engineer will actually touch.
free
20 min
02Safety: light, lasers, eye-contact parts and electricity
Work on ophthalmic instruments without harming the patient's eye, your own eyes or anyone's health: keep light sources within their design, respect laser classes and controlled areas, handle eye-contact parts as contaminated, and test electrical safety after every intervention.
20 min
03Optics and illumination: lamps, cleaning, alignment and mechanics
Replace lamps and judge LED modules correctly, clean the optical surfaces you are allowed to touch without damaging coatings, check the basic alignment a user depends on, and keep sliding bases, joysticks and chin rests working smoothly.
20 min
04Measuring instruments: principles, test eyes and errors
Explain in plain terms how refractometers, keratometers, tonometers, biometers and OCT units measure, verify them with test eyes and reference devices, and trace a wrong result to the patient, the alignment, the optics, the mechanics or the settings.
20 min
05Cameras, PCs and data
Follow the image chain of fundus cameras and OCT units from the sensor to the database, fault-find a camera that is not detected, protect the PC and its unique calibration data, and keep backups and exports working.
20 min
06Fault-finding, planned maintenance and return to service
Fault-find the common ophthalmic complaints by symptom, carry out the Level 1 checks on a laser that will not fire and know where to stop, run a planned maintenance visit, and hand an instrument back with tests and records that prove it is fit for use.
25 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Ophthalmic Equipment Service — Level 1: Slit lamps, refraction, biometry, OCT and lasers
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Hospital biomedical / clinical engineering teams
  • Field engineers in independent service companies
  • Engineers starting to support eye clinics and optical practices

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's procedures or grant authorisation or access to service software.

Will I be able to service treatment and refractive lasers after this course?

No. Level 1 covers laser safety, the user-level checks on a laser that will not fire, symptoms and escalation. Work on laser sources, high-voltage supplies and beam paths needs manufacturer training and authorisation.

What does the certificate say?

Your name, the course, the hours, the date and your exam score, with a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.