Early access · courses are being reviewed by field engineers
Service EngineerAcademy
Academy / Courses / Ophthalmic Equipment Service — Level 2: Fault-Finding
Level 2Certificate course

Ophthalmic Equipment Service — Level 2: Fault-Finding

From the bad image or wrong reading to the failed assembly: illumination, optics, measuring modules, OCT, lasers and data

Part of the program: Ophthalmic Equipment Service Engineer — program (8 h) →

Level 1 taught you to keep an eye clinic's instruments safe, clean and verified. Level 2 starts when the right lamp, a clean window and a reseated cable have not helped. This course teaches the engineer to turn a clinician's complaint into a repeatable test on a test eye or target, place the fault on the instrument's block map, and follow it through illumination, optics and mechanics, refraction, keratometry and tonometry modules, biometers and OCT scanners, treatment lasers, cameras, PCs and data links to the assembly that has actually failed - and then return the instrument to service with the checks, safety tests and records that prove it, while knowing exactly what belongs to the manufacturer.

Not started
01

The quote was for a mainboard. The supply had been failing for months.

  • Mainboards, measuring heads and PC modules are condemned because they reported the error, while a tired power supply, a dusty position sensor or a flat backup battery upstream was the real cause.
  • Instruments are 'corrected' with offsets, local LEDs, home-made filters or reset lamp counters, and the clinic goes on measuring and treating patients with numbers and light that no longer mean what they say.
  • After a repair, refractometers, tonometers and lasers go back to patients without test-eye checks, output measurements, electrical safety tests or a record, and nobody can say whether the instrument was fit for use.
02

After the course you can

01Translate a clinician's complaint into a repeatable test on the manufacturer's test eye or target, place the fault on the block map, and separate suspects by swapping and isolating one thing at a time.
02Fault-find halogen, xenon and LED illumination through supplies, sockets, drivers, cooling and filters, and keep the parts that protect the patient's eye original.
03Locate and clean optical faults without damaging coatings, recognise fog, fungus and misalignment, and repair joysticks, bases, chin rests and drives to the sensor, gear or cable.
04Verify auto-refractometers, keratometers and tonometers on their references, read the error pattern, and keep verification separate from adjustment.
05Diagnose optical biometers, ultrasound probes and OCT scanners by signal quality, reference arm, scanner and camera behaviour, and protect their unique calibration data.
06Work safely on YAG, SLT and photocoagulation lasers, trace the safety chain, aiming beam and output without ever defeating an interlock, and return any ophthalmic instrument to service with performance checks, electrical safety, reprocessed eye-contact parts and a clear record.
03

Curriculum

01The Level 2 method for ophthalmic instruments: symptom, test eye, swap and isolate
Turn a clinician's complaint into a reproducible test on a test eye or target, place the fault in the instrument's block map, separate suspects by swapping and isolating one thing at a time, and know which adjustments are yours and which go back to the manufacturer.
free
22 min
02Illumination: halogen and LED modules, supplies, housings, heat and filters
Trace a dim, uneven, flickering or dead light on a slit lamp, microscope or measuring instrument through the lamp, its socket and supply, the driver, the housing and its cooling, and the filters, and know which parts must stay original because they protect the patient's eye.
22 min
03Optical path and alignment: safe cleaning, fogging and fungus, misalignment, joystick, chin rest and motors
Locate dirt, fog or fungus in an optical path without opening what you should not, clean only what you are allowed to clean without harming coatings, recognise misalignment and its causes, and repair joysticks, bases, chin rests and motor drives down to the screw, sensor, gear or cable.
22 min
04Refraction, keratometry and tonometry: test eyes, calibration checks and typical faults
Verify auto-refractometers, keratometers and non-contact, rebound and applanation tonometers on their reference devices, separate a measurement fault from an alignment, optics, drive or patient problem, and keep verification apart from adjustment.
23 min
05Biometry and OCT: optical biometers, ultrasound A/B probes and OCT scanners
Separate patient, optical, light-source, reference-arm, scanner, camera and PC faults on optical biometers and OCT units, fault-find ultrasound A and B scan probes, protect the unique calibration data, and know which calibrations need the manufacturer's targets and authorisation.
24 min
06Ophthalmic lasers: YAG, SLT and photocoagulation, laser safety, aiming beam and energy checks
Work safely in a laser room under IEC 60825-1 and local rules, fault-find the safety chain, aiming beam, delivery system and energy output of YAG, SLT and photocoagulation lasers without ever defeating an interlock, and know where the manufacturer's work begins.
24 min
07Cameras, PCs, software and data: fundus cameras, licences, DICOM and EMR export, backups
Fault-find fundus camera capture, flash and image faults, treat the instrument PC as part of the device (batteries, BIOS, displays, touchscreens, firmware), report licence and software faults to the manufacturer with the right evidence, and keep exports, DICOM links and backups working without exposing patient data.
22 min
08Complex cases and return to service: performance checks, electrical safety, eye-contact parts, records and fitness for use
Work through multi-fault and intermittent ophthalmic cases with a written timeline, prove a repair with performance checks and electrical safety tests, check that eye-contact parts are safe to use and correctly reprocessed, and write a record that lets the hospital's responsible person decide on clinical use.
24 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Ophthalmic Equipment Service — Level 2: Fault-Finding: From the bad image or wrong reading to the failed assembly: illumination, optics, measuring modules, OCT, lasers and data
5 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 5 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Engineers who have completed Ophthalmic Equipment Service — Level 1 or have equivalent experience
  • Field engineers in independent service companies supporting eye clinics
  • Hospital biomedical / clinical engineering teams that diagnose and repair ophthalmic instruments in-house

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's service procedures, does not grant authorisation or access to service software, passwords, licences or calibration tools, and every repair must still be followed by the checks the manufacturer and national rules require.

Do I need Level 1 first?

Ophthalmic Equipment Service — Level 1 is the prerequisite: the instruments, light, laser and electrical safety basics, cleaning rules, test eyes and the first fault-finding habits are assumed here. Electronics and Power Supplies, Electrical Safety for Medical Equipment and DICOM, PACS and Networks are recommended alongside.

Will I work on lasers?

The course explains laser safety, the safety chain, aiming beam and output checks at the level of a field engineer working under local rules with the laser safety officer. Work inside the laser head, alignment and energy calibration are left to the manufacturer or authorised engineers. Interlocks are never defeated.

Does it teach board-level repair?

It teaches fault-finding to the assembly and the replaceable module. Some field cases end in a component repair; that is workshop work, covered in the Electronics and Power Supplies course.

What does the certificate say?

Your name, the course, the hours, the date and your exam score, with a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.