Fujitsu Celsius M470-2: workstation won't boot, halts at POST
What happened
The workstation failed to start: the boot stopped during POST and the status panel on the front displayed code B0.
What was checked
- Disconnected all peripherals and non-essential devices, then retried the boot.
- Tested the memory one module at a time and cleaned the contacts; the fault stayed.
- Checked the CMOS battery — it measured 3.1 V as reported in the case, which looked acceptable.
- With the rest of the boot chain ruled out, suspicion moved to the graphics card, which was checked with a known-good replacement.
Cause
The engineers found two problems: a failed graphics card that blocked the boot, and a CMOS battery that was effectively dead despite reading 3.1 V as reported in the case — a coin cell can show a normal voltage without load and still sag under it.
What was done
Replaced the graphics card and the CMOS battery. After that the station completed POST and booted normally; the outcome was confirmed in this case.
Safety
Isolate the workstation from the mains and wait before removing the covers, as the power supply can hold a charge, work with ESD precautions, and repeat the electrical safety test before the unit is returned to use.
Lesson: A POST code only narrows the boot chain and does not name the faulty part, so isolate subsystems one at a time — and never trust a coin cell just because it reads its nominal voltage.