HP xw8400: Powers up, no video and no POST beeps

What happened

The workstation starts — fans spin, CPU and chipsets warm up — but there is no video output and no POST beep codes.

What was checked

Cause

A depleted CMOS battery — in this case it read about 1.3 V, too weak to hold the board's startup configuration.

The cause is probable and was not fully confirmed.

What was done

Replace the CMOS coin cell with a fresh one. If that does not bring the machine back, the next steps suggested in the case were the graphics card, the PSU, and capacitor diagnostics on the motherboard. The outcome was reported as probable, not fully confirmed.

Safety

Unplug the workstation from mains and let the power supply discharge before opening the case, use ESD precautions, and if the station is part of an imaging system, make sure the host system is safely shut down before you start work.

Lesson: On an ageing workstation that powers up but never POSTs, rule out the cheap parts first — a dead CMOS battery can stop the boot with no beeps at all.