HP xw9300: freezes and no video after capacitor replacement
What happened
After a partial replacement of visibly bulged electrolytic capacitors, the workstation reportedly ran for about two weeks, then began freezing more and more often and finally stopped producing video, giving a nine-beep BIOS pattern as reported in the case.
What was checked
- Inspected and measured the electrolytics on the board, including capacitors that looked normal externally
- Swapped in another known-good power supply
- Checked the PSU connector pinout and measured the rail voltages
Cause
Probable, per the engineers' own assessment: the replacement electrolytics were of poor quality, and/or defective capacitors remained on the board — they looked and measured normal during the first repair but were failing just the same.
The cause is probable and was not fully confirmed.
What was done
The board was handed over to a service centre for a complete replacement of all electrolytic capacitors; the engineers also recommended opening and checking the power supply itself.
Safety
Before opening the power supply, unplug the workstation and treat the reservoir capacitors as still charged — they can hold a dangerous voltage long after the mains is removed — and after any PSU work run an electrical safety check (ground continuity and leakage) before the machine returns to service.
Lesson: Replacing only the visibly bulged capacitors is rarely enough — when one electrolytic on a board fails, re-cap the whole board with quality parts instead of betting on the ones that still look fine.
Covered in the course: DICOM, PACS and Networks — Level 2: Fault-Finding →
Written from an anonymised case shared by service engineers. It is not a manufacturer instruction and grants no authorisation. Independent note; names are trademarks of their owners.