HP Z400: no inbound remote access or internet while outbound connections work

What happened

The workstation could not be reached from outside with remote-access tools, and the browser had no internet access. However, a session started from the station itself towards an external PC connected normally, so outbound traffic was clearly passing.

What was checked

Cause

As reported in the case, the engineers found that IP address isolation was enabled on the network router: the station's segment was blocked from inbound connections and internet access, while connections initiated by the station itself could still pass.

What was done

The engineers corrected the router configuration to remove the address isolation and allow the station's traffic out and back in. No hardware was replaced — it was purely a network settings change, and afterwards remote access and browsing worked normally.

Safety

Address isolation on a router is often a deliberate protection, so relax such rules only with approval from whoever is responsible for the site's network; and if you open the workstation case, unplug the power cord first.

Lesson: When outbound connections work but inbound ones and internet do not, check the network equipment's rules before blaming the computer.