Sun Sun Blade: workstation fails to boot
What happened
The workstation would not boot; no error codes were reported in the case.
What was checked
- Checked the battery on the timekeeper module — found flat, which explained the failed boot.
Cause
The battery in the timekeeper module had discharged, so the module lost its stored data and the boot process could not complete.
What was done
The engineers replaced the battery. Restoring the boot data afterwards was a procedure from the manufacturer's service documentation, done by authorised personnel. As reported in the case, the workstation started normally after that.
Safety
Isolate the workstation from the mains and observe ESD precautions before opening it, and confirm electrical safety before returning it to use.
Lesson: A dead timekeeper battery alone can stop a workstation from booting, but replacement is only half the fix — the stored boot data must be restored afterwards.