Dräger Primus Anaesthesia Workstation — Model Service
Checkout, maintenance, gas monitoring and fault-finding on the Primus with its electronic mixer, VGC piston ventilator, PGM and UPS power pack
A model course for engineers who have passed Anaesthesia Workstation Service — Level 1. It takes the Primus apart on paper, following its technical documentation: the modules on the CAN bus and the neutral point board, the gas inlet block and the electronic mixer with its tank and proportional valve, the safety O2 adjuster, the VGC with its piston-cylinder unit, rolling seals and vacuum, the heated compact breathing system, the PGM and PGM2 gas monitors, the power pack and UPS batteries. Then the cold start and the manufacturer's test list with its limits, the maintenance parts and what the machine calibrates by itself, alarms and safety mode, leak, ventilator, flow and gas monitoring faults, power and board faults, typical replacements and a full return to service. Engineers who know the Fabius are told where the Primus differs. Independent course: not affiliated with or endorsed by Drägerwerk AG. Dräger and Primus are trademarks of their owner.
No flow tubes, a mixer that thinks, a piston that waits for vacuum and a battery pack that runs the whole theatre.
- Engineers arrive at a Primus with Fabius or bellows-machine habits and look for flow tubes, a ratio controller or drive gas; instead they find an electronic mixer, a ventilator that will not move until its vacuum is right and a gas monitor built into the machine.
- Typical calls end with new O2 cells, new flow sensors or a reassembled breathing system while the real cause is a dirty valve seat, a rolling seal fitted inside out, a tired pair of UPS batteries, a clogged filter mat or a power pack input stage.
- The self-test passes, its PASS is taken as proof, and the machine goes back to theatre without the instrument checkout, the gas monitor checks or the 30-minute battery run.
After the course you can
Curriculum
Identify the Primus configuration and software in front of you, name its modules, boards and pneumatic components, and follow the gas from the pipeline inlet through the electronic mixer, vaporiser, compact breathing system and piston ventilator to the scavenger, knowing where it differs from a Fabius.free
23 min02Cold start, self-test and the engineer's checkout
Explain what the Primus cold start and self-test prove and what they cannot, run the manufacturer's test list in a sound order with its limits, and say what each failed step points to.25 min03Preventive maintenance, consumables and calibration
Plan and carry out a Primus maintenance visit: know which parts the documentation replaces and at what intervals it states, why each matters, which calibrations the machine does itself and under what conditions, and what you verify and record.23 min04Alarms, safety mode and pneumatic fault-finding
Read Primus alarms, safety mode and machine states correctly, and isolate faults in the supply and mixer, the breathing system, the VGC ventilator, flow measurement and the gas monitor in a cheap-first order.25 min05Power pack, boards, replacements and return to service
Trace Primus power and communication faults through the power pack, the neutral point and the module boards, prepare safely for disassembly, know what each typical replacement involves and what must be checked after it, and release the machine only after full verification.25 min—Exam
25 · 40 min · 75 %
The certificate
Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.
Who it is for
Who it is for
- Engineers who have completed Anaesthesia Workstation Service — Level 1 or have equivalent experience
- Hospital biomedical teams and independent service companies maintaining Dräger Primus workstations, including engineers moving over from the Fabius
Who teaches
Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.
FAQ
Is this Dräger training?
No. It is an independent course, not affiliated with or endorsed by Drägerwerk AG. Dräger and Primus are trademarks of their owner. The course does not replace the manufacturer's procedures and does not grant authorisation, passwords, option codes or access to service software.
Which machines does it cover?
The Primus anaesthesia workstation as described in its technical documentation, revision 6.0, for software up to and from version 2.n, with PGM or PGM2 gas monitoring. Later family members and newer software have their own documentation; where they differ, the course tells you to use it.
I already know the Fabius. Is this worth it?
Yes. The piston and the compact breathing system will look familiar, but the electronic mixer, the safety O2 adjuster, the built-in gas monitor, the VGC pneumatic block and the UPS power pack are different, and the course points out each difference as it comes.
Do I need the technical documentation?
You should have the manufacturer's technical documentation and instructions for use for the machine you work on. The course explains and orders the work; the exact procedures, limits and part numbers come from the documentation for your machine and revision.
Does it cover software upgrades and option activation?
Only at procedure level: who may do it and what to record and check before and after. The steps themselves are the manufacturer's and are done by authorised personnel with the proper tools.
What does the certificate say?
Dräger Primus Anaesthesia Workstation — Model Service (Endorsement), with your name, the hours, the date and your exam score, a unique number and a public verification page.
Can my company buy seats for a team?
Yes: five seats and a progress overview for the manager.
Languages?
English and Russian.