Early access: courses are being reviewed by field engineers
Service EngineerAcademy
Academy / Courses / GE Vivid 7 and Vivid i Cardiovascular Ultrasound — Model Service
ModelCertificate course

GE Vivid 7 and Vivid i Cardiovascular Ultrasound — Model Service

Architecture, start-up, maintenance, diagnostics and repair of the cart Vivid 7 and the portable Vivid i, side by side

Start the free lesson
$99 per engineer · the first lesson is free
For teams: 5 seats for $390 (the price of 4) · Get a quote · How team training works

A model course for engineers who have passed Ultrasound Service — Level 1 and, ideally, Level 2 and Ultrasound Probes. It takes two machines apart on paper: the Vivid 7 cart, with its card rack of separate front end boards, PC back end with UPS battery and isolating transformer, and the Vivid i portable, with its three-board front end, power supply, lithium-ion battery and five fans. It reads the power-up of each as a diagnostic sequence, explains the service platform logs and built-in tests, follows the manuals' preventive maintenance with GE's safety limits, localises faults from no boot to a single dead probe with field cases from the Vivid family, and covers replacement, calibration, software at procedure level and return to service. Engineers who know LOGIQ are told where Vivid is different. Independent course: not affiliated with or endorsed by GE HealthCare. GE, Vivid and LOGIQ are trademarks of their owners.

Not started
01

You know how an ultrasound system works. This course is about how a cardiac Vivid fails.

  • Vivid 7 and Vivid i systems still run in echo labs, wards and private cardiology practices, most of them long out of manufacturer contracts. Engineers meet them with general ultrasound knowledge and a service manual that assumes factory training.
  • Typical calls end in replaced boards and reloaded software while the cause is a drained UPS battery, a clogged filter, blocked vents, an aged Vivid i battery, one delaminated probe or a calibration that was never run after a repair.
  • Data, options and calibration are lost in repairs: no backup before a reload, a board of the wrong revision for the build level, a disk or back end replaced without settling the system's licences.
02

After the course you can

01Identify a Vivid 7 or Vivid i, its build level, software and options from what the machine and its labels report, and name the main assemblies of each and their place in the signal and power path.
02Check a site against the manuals, read the start-up of both machines as a diagnostic sequence, set up peripherals and DICOM at a general level, and know which logs and built-in tests exist and what they tell you.
03Plan and perform preventive maintenance with probe inspection, cleaning, battery and cooling checks and electrical safety tests against GE's limits, and record it so it can be trended.
04Localise faults to power, back end, front end, probe, ECG or peripherals using the start-up stages, logs, built-in tests, calibration and substitution, with real cases from the Vivid family.
05Prepare a repair without losing data or creating hazards, match replacement parts to the build, run the calibrations the manuals require, handle software and options at procedure level, and return the system to service with complete records.
03

Curriculum

01The Vivid platform: Vivid 7 and Vivid i side by side, and the signal path of each
Identify which Vivid you are facing and at what build level, name the main assemblies of the Vivid 7 and the Vivid i and their place in the signal and power path, and know where the two machines differ from each other and from a LOGIQ before you open either.
free
22 min
02Setup, start-up and the service platform: reading both machines before you touch them
Check a site and an installation against the manuals' requirements, read the power-up of a Vivid 7 and a Vivid i as a diagnostic sequence, set up peripherals and DICOM at a general level, and know which logs and built-in tests exist and what each one tells you.
23 min
03Care and preventive maintenance: what the Vivid manuals ask for and why
Plan and carry out a PM visit on a Vivid 7 or a Vivid i with the intervals, checks, cleaning, probe inspection and electrical safety limits that the manuals state, and record the results so that the next engineer can trend them.
21 min
04Diagnostics and fault-finding: from no boot to a single dead probe
Localise a Vivid 7 or Vivid i fault to power, back end, front end, probe, ECG or peripherals using the start-up stages, the logs, the built-in tests and substitution, in an order that costs least and risks least.
24 min
05Replacement and return to service: FRUs, software and the checks before clinical use
Prepare a Vivid 7 or Vivid i repair without losing data or creating hazards, understand what each typical replacement involves and what must be checked after it, handle software reload and options at procedure level, and return the system to clinical use with complete records.
22 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
GE Vivid 7 and Vivid i Ultrasound — Model Service (Endorsement)
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Engineers who have completed Ultrasound Service — Level 1 or have equivalent experience
  • Hospital biomedical teams and independent service companies maintaining GE Vivid 7 and Vivid i systems

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this GE HealthCare training?

No. It is an independent course, not affiliated with or endorsed by GE HealthCare. GE, Vivid and LOGIQ are trademarks of their owners. The course does not replace the manufacturer's procedures and does not grant authorisation, passwords, service access, option keys or proprietary service tools.

Which Vivid models does it cover?

The Vivid 7 and Vivid 7 PRO as described in their 2002 service manual (build levels BT'01 and BT'02), and the Vivid i as described in its 2007 service manual. Later Vivid systems appear only in field cases, marked with the model they came from; their boards, voltages and procedures come from their own documentation.

These are old systems. Can I still get parts?

Availability varies. Many parts now come from refurbishers or donor units. The course shows how to match a part to the build level and revision tables in the manual and how to test it before closing the job, but it cannot promise that any part is still obtainable.

Do I need the service manual?

You should have the manufacturer's service and user documentation for the system you work on. The course explains and orders the work; exact procedures, limits and part numbers come from the documentation for your unit, build level and software.

Does it cover software reload and options?

Only at procedure level: what to back up and record before, what to check after, and that software, licences and options are handled per GE's procedure by authorised personnel with the valid codes for that system. It does not cover obtaining, generating or transferring codes or keys, or any way around software protection.

What does the certificate say?

GE Vivid 7 and Vivid i Ultrasound — Model Service (Endorsement), with your name, the hours, the date and your exam score, a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.