Academy / Courses / Medical Imagers and Film Printers — Level 1
Level 1Certificate course

Medical Imagers and Film Printers — Level 1

Dry and laser imagers, film, DICOM print and image quality

Part of the program: Medical Imager and Film Printer Engineer — program (7 h) →

A film loaded upside down, an expired box, a dirty roller, a filter nobody changed, a modality that sends the wrong film size — most imager downtime starts with something cheap and checkable. This course teaches the engineer who looks after dry and laser imagers to understand how the film is picked, exposed and developed, to read artefacts and error groups, to sort out DICOM print settings, and to carry out PM and QC before handing the printer back.

Not started
01

Most film printer calls are not about the laser or the head. They are about dust, a roller, the film box or one wrong setting.

  • When the film printer stops, CT, MRI and X-ray keep scanning but nobody gets a hard copy, and the call always comes as an emergency.
  • Most printer faults look like expensive ones — a dead thermal head, a weak laser, a failed board — while the real cause is film, dust, a roller, a spring or a configuration mismatch.
  • Manufacturer training on imagers is rare, model-specific and closed to independent engineers; the principles shared by every dry imager are seldom taught on their own.
02

After the course you can

01Tell direct thermal, laser photothermographic and legacy wet laser imagers apart, and name the main assemblies along the film path and what each one does.
02Work safely around an enclosed laser, a hot developer drum, moving rollers and mains power, and handle and store film so that it is not fogged or damaged before it is used.
03Follow the film through pick-up, transport and exit, use the sensors and jam areas to locate a jam, and clean and inspect rollers so that jams do not come back.
04Explain how density is made by a thermal head or by laser exposure and heat development, run and interpret the step-wedge calibration, and read lines, bands and density drift back to their cause.
05Set up and check a DICOM print connection: AE titles, port, film sizes and layouts, density and LUT settings, and recognise the typical modality-to-printer mismatches.
06Find faults by group (supply, transport, exposure, processor, densitometer, network, software), carry out PM by the manufacturer's checklist, and run test prints and QC before returning the printer to use.
03

Curriculum

01Imagers in the imaging department: three technologies, one film path
Recognise which kind of imager you are standing in front of, name its main assemblies in the order the film meets them, and say which assembly a complaint most likely belongs to.
free
20 min
02Safety: laser, heat, rollers, mains — and the film itself
Open and work inside an imager without injuring yourself or damaging it, and handle, load and store film so that it reaches the image path unfogged and undamaged.
20 min
03Film transport: pick-up, rollers, sensors and jams
Follow a sheet from the pack to the output tray, use the jam area and the sensor that tripped to locate the cause, and clean and inspect the transport so that the same jam does not return.
20 min
04Image formation and quality: head, laser, heat, density and artefacts
Explain how density is produced and controlled in thermal and laser dry imagers, read a density calibration result, and trace lines, bands, streaks and density drift to the part of the machine that causes them.
25 min
05DICOM print and connection: AE titles, film sizes, layouts and LUTs
Set up and check a DICOM print connection between a modality and an imager, and recognise the configuration mismatches that cause no print, wrong size, wrong density or prints from the wrong sender.
20 min
06Fault-finding, PM and return to service
Sort an imager fault by error group and symptom, carry out a PM by the manufacturer's checklist, and run test prints and QC so that you can hand the imager back with evidence that it works.
25 min
—Exam
25 · 40 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Medical Imagers and Film Printers — Level 1: Dry and laser imagers, film, DICOM print and image quality
3 hours · score 86 %No. SEA-US1-000000-K7QF3M · verify at /verify/
The 3 training hours may be self-reported as continuing education (Category IV) toward renewal of AAMI CBET/CRES/CLES certification.
05

Who it is for

Who it is for

  • Hospital biomedical / clinical engineering teams
  • Field engineers in independent service companies

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's procedures or grant authorisation or access to service software.

What does the certificate say?

Your name, the course, the hours, the date and your exam score, with a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.