Where to train as an MRI service engineer: manufacturer, independent and online options compared

2026-11-21

MRI is the hardest modality to learn on the job. The magnet, cryogenics, RF and gradients each need their own knowledge, and mistakes are expensive and can be dangerous. There are three kinds of training. This guide compares them using only what each provider publishes. Prices and dates were checked in November 2026; always confirm them with the provider.

Quick comparison

ProviderTypeFormatLengthPublished priceWho can enrol
GE HealthCare, MR Proficient Service TrainingManufacturerClassroom and lab in Waukesha, WI, plus online prerequisites10 days (store page)$29,500 tuition; $33,250 with lodging and airfareCustomer biomedical engineers
Siemens Healthineers technical trainingManufacturerClassroom, hands-on, on-site and virtual (Cary, NC)One-week blocksNot publishedDepends on your service contract
Philips Learning Connection, MR Service Training HEManufacturerInstructor-led; MR Concepts HE is 8 hours of eLearning10 daysNot publishedHospital engineers
Canon Medical (USA) service educationManufacturerOnline self-paced, virtual classes, on-site in Irvine, CANot publishedNot publishedNot published
RSTI, Principles of Servicing MRI SystemsIndependent, not tied to one manufacturerClassroom with daily hands-on lab, Solon, Ohio2 weeks (10 days)$12,995Engineers with electronics schooling or experience
Service Engineer Academy, MRI Service Level 1Independent, onlineOnline lessons, exam, certificateAbout 4 hours$149 per engineer (founder price); team of 5 for $590Anyone; first lesson free

Manufacturer training

Manufacturer courses are the only route to service software, licences and authorisation for a specific scanner. If your hospital or company will service a GE, Siemens or Philips magnet in-house, you will need one of them at some point.

  • GE HealthCare publishes its price. MR Proficient Service Training is listed for biomedical engineers. It costs $29,500 for tuition only, or $33,250 with lodging and airfare. The fee is nonrefundable and must be used within 24 months. GE also teaches service on some other makers' systems, for example a 5-day Siemens Aera/Skyra course at $18,500, which needs MR Proficient or equivalent and a year of MR field service.
  • Siemens Healthineers offers technical training in Cary, NC, and on site. Eligibility depends on the service contract; an inquiry does not guarantee a place. MRI course lists and prices are not published.
  • Philips lists MR courses for hospital engineers: MR Concepts HE (8 hours of eLearning for engineers new to MR) and MR Service Training HE (10 days, covering Achieva, Ingenia and Multiva). Location and price are not published.
  • Canon Medical offers online self-paced service training with the same content and licences its own engineers get, plus virtual and on-site classes. MR courses and prices are not published.

Good for: model-specific authorisation and software access. Watch out for: cost, travel, waiting lists, and eligibility tied to a contract.

Independent classroom training

RSTI in Solon, Ohio, runs Principles of Servicing MRI Systems for engineers with little or no MRI experience. It is 10 days with a hands-on lab every day, 4 CEUs, and costs $12,995. It does not depend on one manufacturer, and RSTI adds follow-on courses for Siemens and GE systems.

We searched for independent MRI field-service courses with a published schedule and fee in Europe, the Middle East and India and did not find one. Most results were for scanner operators or general biomedical diplomas.

Good for: a first solid grounding before a factory course, with real hardware. Watch out for: travel to the US and the fee.

Online training

Online courses do not replace hands-on work on a magnet, and they do not give you manufacturer authorisation. What they do well is the method: how an MRI system is built, how to do preventive maintenance safely, how to narrow a fault down to the subsystem before calling for parts or the factory.

  • Service Engineer Academy (that is us) teaches MRI service online and vendor-neutral. MRI Service — Level 1 costs $149 per engineer at the founder price, and the first lesson is free. The MRI Service Engineer full program adds Level 2, cryogenics and the helium system, and a GE platform course, for $419. Each course ends with an exam and a certificate. For a team, 5 seats cost the price of 4.
  • Free physics resources: MRIquestions.com by Allen D. Elster is free to use. IMAIOS e-MRI is an interactive course on MRI physics and instrumentation; check its pricing page.

Good for: onboarding new engineers, preparing before an expensive factory course, and keeping a whole team at the same baseline. Watch out for: you still need supervised practice on real systems.

How to combine them

A practical path for a hospital or service company:

  1. Start new engineers with free physics material and an online MRI service course, so they arrive at a factory class already knowing the system.
  2. Send one or two engineers to manufacturer training for the scanners you service in-house, to get authorisation and software access.
  3. Use an independent classroom course where you need hands-on depth but not a specific manufacturer's authorisation.
  4. Record each step: course, hours, exam score, observed practical task and sign-off. See our guide on documenting the competency of biomedical engineers.

If you train a team, see training for teams.

FAQ

Sources

  • GE HealthCare, MR Proficient Service Training: https://services.gehealthcare.com/gehcstorefront/p/CR-0000644
  • GE HealthCare, Siemens Aera/Skyra service course: https://services.gehealthcare.com/gehcstorefront/p/CR-0004674
  • Siemens Healthineers, technical training: https://www.siemens-healthineers.com/en-us/equipment-services/shared-services/technical-training
  • Philips Learning Connection, MR for biomedical engineers: https://www.learningconnection.philips.com/en/catalog/profession/biomedical-engineers/magnetic-resonance
  • Canon Medical, service education: https://learning.us.medical.canon/educational-resources/service/overview/
  • RSTI, Principles of Servicing MRI Systems: https://rsti-training.com/courses/principles-of-servicing-mri-systems/
  • MRIquestions.com: https://mriquestions.com/index.html
  • IMAIOS e-MRI: https://www.imaios.com/en/e-mri
How much does MRI service training cost?

Published prices range from $12,995 for a 10-day independent classroom course (RSTI) to $29,500 for GE HealthCare's 10-day MR Proficient course, before travel. Siemens, Philips and Canon do not publish prices. Online courses cost from about $149.

Can a hospital biomedical engineer attend manufacturer MRI service training?

Often yes. GE lists its course for biomedical engineers and Philips for hospital engineers. At Siemens, eligibility depends on the service contract.

Is online MRI service training enough to service a scanner?

No. It teaches the method and the system, but servicing a magnet also needs supervised hands-on work and, for many tasks, the manufacturer's software and authorisation.

Where can I learn MRI physics for free?

MRIquestions.com by Allen D. Elster is free to use.