Early access · courses are being reviewed by field engineers
Service EngineerAcademy
Academy / Courses / CT Service — Level 1
Level 1Certificate course

CT Service — Level 1

Safety, calibration and preventive maintenance

Air conditioning, dirty filters, a skipped air calibration, a slip ring nobody cleaned — most CT failures start with something cheap that nobody checked. This course teaches the engineer who maintains a CT scanner to keep it safe, calibrated and running.

Not started
01

The tube is the most expensive part. Most CT downtime starts somewhere cheaper.

  • A CT scanner that stops loses a full day of patients, and most stoppages start with something cheap: a hot room, dusty filters, a skipped calibration, worn slip ring brushes.
  • The tube costs as much as a car, and how it is warmed up, loaded and cooled decides whether it lasts its expected life or fails early.
  • Manufacturer courses are expensive, model-specific and often closed to independent engineers; the safety and maintenance basics every CT shares are rarely taught on their own.
02

After the course you can

01Understand what stands and what rotates in a CT scanner, and follow the power, image and control chains from the wall to the reconstructed slice.
02Work safely around high voltage, ionising radiation and a heavy rotating gantry: lock-out, discharge, rotor locks, interlocks and a personal dosimeter.
03Protect the tube: warm-up and conditioning, heat capacity and cooling waits, and the early signs of an ageing tube.
04Run and audit the operator's air calibration and daily phantom check, and know where calibration ends and a detector fault begins.
05Keep all three cooling loops - tube oil, gantry, room - working, and carry out planned maintenance by checklist: slip ring, drive, table, lasers, cables, backups.
06Check image quality with the ACR phantom against a baseline and write a maintenance report with a tube log, scope limits and a clear fitness-for-use statement.
03

Curriculum

01How a CT scanner is built: what stands still and what rotates
Place any CT complaint on the chain from mains to PACS, say whether the faulty part sits on the stationary side or on the rotor, and decide whether the cause lies before or after the patient.
free
20 min
02The power chain and high voltage: isolate, discharge, verify
Follow CT power from the supply to the X-ray tube, check supply quality correctly, and make a CT gantry safe for work by isolation, lock-out, waiting for stored energy to discharge and verifying absence of voltage.
22 min
03Radiation safety for the CT engineer
Work on a CT scanner so that your own radiation dose stays as low as reasonably achievable: never in the room during exposure, interlocks and warning lights checked and never defeated, personal dosimeter worn, and shielding problems reported.
22 min
04The X-ray tube: warm-up, conditioning and heat
Explain why a CT tube must be warmed up and conditioned, read cooling waits correctly, track tube counters and error logs at every visit, and recognise the combined signs that a tube is approaching end of life.
22 min
05Operator calibrations: air calibration and the daily phantom check
Know what the air calibration and the daily phantom check actually correct and measure, run or review them correctly, and recognise the point at which calibration stops being the answer and a detector or service-level fault begins.
20 min
06Cooling: three loops in series
Trace the heat of a CT scanner from the anode to the outside air through three loops, check and clean each loop on a maintenance visit, and tell a genuine cooling fault from a room that cannot carry the heat or a workload that exceeds the design.
20 min
07Planned maintenance by checklist
Carry out a CT planned maintenance visit in a safe, repeatable order - preparation, safe access, gantry mechanics and slip ring, table and lasers, cables and interlocks, console and backups, then return to service - recording as-found and as-left condition at every step.
25 min
08Image quality control with the ACR phantom, and the maintenance report
Use an independent phantom such as the ACR CT accreditation phantom to check CT number accuracy, noise, uniformity and low contrast against a baseline, and write a maintenance report with as-found and as-left results, a tube log, cooling remarks and a clear statement of scope and fitness for use.
25 min
—Exam
30 · 45 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
CT Service — Level 1: Safety, calibration and preventive maintenance
4 hours · score 86 %No. SEA-0000-000000 · verify at /verify/
05

Who it is for

Who it is for

  • Hospital biomedical / clinical engineering teams
  • Field engineers in independent service companies

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's procedures or grant authorisation or access to service software.

What does the certificate say?

Your name, the course, the hours, the date and your exam score, with a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.