Early access · courses are being reviewed by field engineers
Service EngineerAcademy
Academy / Courses / Patient Monitor Service — Level 1
Level 1Certificate course

Patient Monitor Service — Level 1

Parameters, simulators and preventive maintenance

Part of the program: Patient Monitor Service — full program (12 h) →

ECG, SpO2, NIBP, IBP, temperature, CO2 — each parameter fails in its own way, and most failures are accessories. This course teaches the engineer to test every parameter with a simulator, separate accessory faults from module faults and maintain monitors to a standard that survives an audit.

Not started
01

Half of all monitor faults are a cable.

  • A monitor is the only thing watching the patient: a dead SpO2 sensor, a quiet alarm or a monitor missing from the central station goes unnoticed until something happens.
  • Most monitor faults are accessories - cables, sensors, cuffs, sample lines - yet whole monitors are swapped or sent away because nobody separated the accessory from the module.
  • PM is often a sticker and 'checked, OK': no simulator values, no manometer, no leakage on each applied part, and nothing that survives an audit or an incident review.
02

After the course you can

01Understand how each parameter is measured - ECG, oscillometric NIBP, SpO2, IBP, temperature, capnography - well enough to know what can go wrong in each chain.
02Know the monitor's architecture and accessories: modules, cables, sensors, compatibility between technologies, the central station and the room.
03Protect the patient: applied parts BF and CF, defibrillation protection, leakage paths through damaged or wrong accessories, safe cleaning.
04Run a planned maintenance in a fixed order: inspection, accessories, every alarm and its volume, battery, logs, clock and network - and restore the hospital's configuration.
05Verify every channel with a patient simulator, NIBP with a calibrated manometer (static pressure, leak, over-pressure) and capnography with certified test gas.
06Measure leakage on every applied part per IEC 62353, decide pass or fail on values, and write a report with instruments, values and limits.
03

Curriculum

01What a patient monitor measures and how
Understand the measuring principle of each monitor parameter - ECG, SpO2, NIBP, IBP, temperature and CO2 - well enough to know what a simulator can and cannot prove, and where each channel usually fails.
free
20 min
02Monitor architecture, accessories and the installation
Know how a monitor is built from a host, parameter modules, accessories and a network, recognise compatible and incompatible accessories, and check that the bedspace installation supports safe monitoring.
20 min
03Patient safety: applied parts, defibrillation protection and leakage
Explain why a monitor's patient connections are isolated, recognise BF, CF and defibrillation-proof markings, and make conservative decisions about damaged cables, cleaning, batteries and testing so that service never reduces patient protection.
22 min
04Planned maintenance: inspection and functional check
Carry out the inspection and functional part of a monitor PM - accessories, alarms and their volume, battery, logs, clock and network - in a fixed order, and hand the monitor back with the hospital's configuration intact.
20 min
05Verification with a patient simulator, a manometer and test gas
Verify every monitor channel with an independent, calibrated instrument - ECG, respiration, SpO2, IBP and temperature with a simulator, NIBP with a manometer, CO2 with certified test gas - and record set, displayed and pass or fail against the manufacturer's limits.
25 min
06Electrical safety per IEC 62353 and the service report
Test a patient monitor to IEC 62353 - protective earth, equipment leakage and applied part leakage on every applied part - decide pass or fail on recorded values, and write a PM report that would stand up in an audit or an incident review.
25 min
—Exam
30 · 45 min · 75 %
04

The certificate

Pass the exam and get a certificate of course completion with your name, hours and score. Every certificate has a unique number and a public verification page, so an employer or a customer can check it in one click. It confirms completion of the course; it is not an educational document (diploma) and not a manufacturer authorisation.

Certificate of course completion
Alex Example
has completed the course
Patient Monitor Service — Level 1: Parameters, simulators and preventive maintenance
3 hours · score 86 %No. SEA-0000-000000 · verify at /verify/
05

Who it is for

Who it is for

  • Hospital biomedical / clinical engineering teams
  • Field engineers in independent service companies

Who teaches

Written by a service engineer working with medical equipment since 2014, including 6.5 years at GE Healthcare and service supervision at Mindray, together with the engineers of Service Engineer.

06

FAQ

Is this manufacturer training?

No. It is independent, vendor-neutral training. It does not replace the manufacturer's procedures or grant authorisation or access to service software.

What does the certificate say?

Your name, the course, the hours, the date and your exam score, with a unique number and a public verification page.

Can my company buy seats for a team?

Yes: five seats and a progress overview for the manager.

Languages?

English and Russian.